Intended for healthcare professionals

CCBYNC Open access
Research

Hysterectomy, endometrial ablation, and levonorgestrel releasing intrauterine system (Mirena) for treatment of heavy menstrual bleeding: cost effectiveness analysis

BMJ 2011; 342 doi: https://doi.org/10.1136/bmj.d2202 (Published 26 April 2011) Cite this as: BMJ 2011;342:d2202
  1. T E Roberts, professor of health economics1,
  2. A Tsourapas, research fellow1,
  3. L J Middleton, statistician2,
  4. R Champaneria, research associate2,
  5. J P Daniels, senior research fellow2,
  6. K G Cooper, consultant gynaecologist3,
  7. S Bhattacharya, professor of obstetrics and gynaecology4,
  8. P M Barton, senior lecturer in mathematical modelling1
  1. 1Health Economics Unit, School of Health and Population Sciences, Public Health Building, University of Birmingham, Birmingham B15 2TT, UK
  2. 2Birmingham Clinical Trials Unit, University of Birmingham, Birmingham
  3. 3Department of Obstetrics and Gynaecology, Aberdeen Royal Infirmary, Foresterhill, Aberdeen AB25 2ZN
  4. 4Section of Applied Clinical Sciences, Division of Applied Health Sciences, School of Medicine and Dentistry, University of Aberdeen, Aberdeen Maternity Hospital, Foresterhill, Aberdeen
  1. Correspondence to: T E Roberts T.E.Roberts{at}bham.ac.uk
  • Accepted 16 February 2011

Abstract

Objective To undertake a cost effectiveness analysis comparing first and second generation endometrial ablative techniques, hysterectomy, and the levonorgestrel releasing intrauterine system (Mirena) for treating heavy menstrual bleeding.

Design Model based economic evaluation with data from an individual patient data meta-analysis supplemented with cost and outcome data from published sources taking an NHS (National Health Service) perspective. A state transition (Markov) model was developed, the structure being informed by the reviews of the trials and clinical input. A subgroup analysis, one way sensitivity analysis, and probabilistic sensitivity analysis were also carried out.

Population Four hypothetical cohorts of women with heavy menstrual bleeding.

Interventions One of four alternative strategies: Mirena, first or second generation endometrial ablation techniques, or hysterectomy.

Main outcome measures Cost effectiveness based on incremental cost per quality adjusted life year (QALY).

Results Hysterectomy is the preferred strategy for the first intervention for heavy menstrual bleeding. Although hysterectomy is more expensive, it produces more QALYs relative to other remaining strategies and is likely to be considered cost effective. The incremental cost effectiveness ratio for hysterectomy compared with Mirena is £1440 (€1633, $2350) per additional QALY. The incremental cost effectiveness ratio for hysterectomy compared with second generation ablation is £970 per additional QALY.

Conclusion In light of the acceptable thresholds used by the National Institute for Health and Clinical Excellence, hysterectomy would be considered the preferred strategy for the treatment of heavy menstrual bleeding. The results concur with those of other studies but are highly sensitive to utility values used in the analysis.

Introduction

Heavy menstrual bleeding is a common problem1 that affects about 1.5 million women in England and Wales.2 The condition prompts one in 20 women of reproductive age to consult her general practitioner and accounts for 20% of all referrals to gynaecology outpatients.2 Heavy menstrual bleeding can cause considerable distress to women by affecting their performance at work as well as social activities and leads to a measurable reduction in quality of life.3 Traditionally, the definitive treatment was surgery: in the past, by the age of 55 one in five women in the United Kingdom had had a hysterectomy,4 over half of which were for heavy menstrual bleeding.5

First line treatments for heavy menstrual bleeding include oral drug regimens such as tranexamic acid, mefenamic acid, and the combined contraceptive pill. More recently an alternative medical option is available in the levonorgestrel intrauterine system (Mirena). This intrauterine contraceptive device works to reduce menstrual loss by local release of progestogen and can be fitted in primary or secondary care.6 Surgical treatments include first and second generation endometrial ablation, which destroys the lining of the cavity of the uterus (endometrium).6 First generation techniques typically required direct hysteroscopic vision and include endometrial laser ablation, transcervical resection of the endometrium, and rollerball ablation. Second generation techniques are typically non-hysteroscopic, vision control is not required, and they tend to be easier to perform. These latter techniques include fluid filled thermal balloon endometrial ablation, radiofrequency (thermoregulated) balloon endometrial ablation, and microwave endometrial ablation (MEA). Hysterectomy, surgical removal of the uterus, was the only surgical solution until the advent of ablation techniques and is still used when other treatments fail.6

Between 2000 and 2005 the number of hysterectomies performed for heavy menstrual bleeding fell from over 20 000 to just over 7000. Instead, 9701 women underwent endometrial ablation; over half of these (5457) were performed by means of second generation (non-hysteroscopic) techniques.6 7 The use of Mirena has increased concurrently, though its widespread use for contraception across many clinical settings in primary and secondary care means that it is difficult to gather accurate data on numbers prescribed for heavy menstrual bleeding. Though some follow-up studies have concentrated on short and medium term outcomes after hysterectomy and endometrial ablation, there have been few long term controlled comparisons of hysterectomy with ablation techniques in women with heavy menstrual bleeding.7

As part of a wider NIHR Health Technology Assessment project tasked to assess the existing evidence on effectiveness through a meta-analysis of non-oral treatments for heavy menstrual bleeding using data on individual patients,6 we carried out an economic evaluation to determine the relative cost effectiveness of the four alternative non-oral interventions—hysterectomy, first and second generation endometrial ablation, and Mirena—for the treatment of heavy menstrual bleeding. Although it is a non-surgical intervention, we included Mirena in the analysis for comparison primarily because it is the intervention that the National Institute for Health and Clinical (NICE) favours for this condition.8

Methods

We have already published a systematic review and individual patient data meta-analysis of available evidence.7 Briefly, we used individual patient data as far as possible, supplemented with the trial data as necessary. Individual patient data on 2814 women were available from 17 of the 30 randomised controlled trials identified (14 trials (2448 women) for first versus second generation endometrial ablation; seven trials (1127 women) for hysterectomy versus first generation endometrial ablation; five trials (304 women) for second generation endometrial ablation versus Mirena; three trials (190 women) for first generation endometrial ablation versus Mirena; one trial (236 women) for hysterectomy versus Mirena). Direct and indirect comparisons were made when appropriate to assess the effect of interventions on the primary outcome measure of patient’s dissatisfaction.

Given the reliance on secondary data and the nature of available data, the model based economic evaluation takes the form of a cost utility analysis and was carried out from a UK National Health Service (NHS) perspective in a secondary care setting.

Cost effectiveness model

The model was developed through consultation within the research team, drawing on the requisite clinical and modelling expertise. We developed a new state transition (Markov) model in Microsoft Excel, using as a starting point an existing model developed by Garside et al.9 In running the model we compared the progress of a hypothetical cohort of women with heavy menstrual bleeding when they are treated by four alternative interventions: Mirena, first generation endometrial ablation techniques, second generation endometrial ablation techniques, and hysterectomy. We compared the four alternative interventions in four alternative treatment strategies. The pathway of the strategy is defined by the intervention that is tried first. For example, the second generation endometrial ablation strategy is so called because that is the intervention first in the pathway; if it works for any particular woman, her treatment will stop there. However, the pathways are constructed to follow logical clinical evidence based progression. Each progression in the pathway reflects the next likely option, assuming that the patient returns seeking further treatment because she is dissatisfied with the outcome from the previous treatment. So, for instance, the strategy referred to as second generation ablation might also include a repeat ablation and even a hysterectomy later in the strategy. We include a strategy to represent first generation endometrial ablation and a separate strategy to represent second generation endometrial ablation. Although first generation ablation might sound like an approach that has been superseded by second generation ablative techniques, outcomes from first generation techniques are still acceptable, and the technique is sometimes considered more versatile than some second generation approaches. For example, they are used if visualising the cavity at time of treatment is deemed important. Furthermore, first generation ablative techniques must be the technique of choice when repeat treatments are required, whether or not the preceding treatment was first or second generation ablation. Neither of the ablative techniques preserves fertility. The only intervention that preserves fertility is Mirena. The hysterectomy strategy is offered to a woman for whom the only acceptable outcome is amenorrhoea. In the hysterectomy strategy, all other steps are bypassed and hysterectomy is the only intervention.

Figure 1 shows the clinical pathways on which the model is based. Health states are shown in boxes, and arrows show the transitions that can occur. The health states and pathways are the same for both types of endometrial ablation techniques. Table 1 presents a summary of the health states for each pathway.

Figure1

Fig 1 Clinical pathways within model for determination of cost effectiveness of different treatments for heavy menstrual bleeding. Names of strategies denote first intervention undertaken

Table 1

 Definition of health states for women after respective intervention pathways for treatment of heavy menstrual bleeding

View this table:

In this model, the hypothetical cohort of patients moves between discrete health states to replicate the natural course of the condition, with each state having associated costs and quality of life. In such a model, transition probabilities, costs, and quality of life differ according to the use of the alternative techniques used to treat the clinical problem. The difference in outcome and costs between cohorts yields estimates of cost effectiveness.

We compared a cohort of 10 000 eligible women for each strategy. The starting age of women in the model is 42, as this is the mean age of women in all the ablation randomised controlled trials, and the period covered is a total of 10 years.6 7 10 We assume that all women will become menopausal at the age of 52, the average age of menopause in the UK. We considered these assumptions to reflect the evidence in the literature.6 These are also the assumptions used by earlier authors.8 Each model cycle lasts one month, representing the typical menstrual cycle. The death rate from causes other than procedures for heavy menstrual bleeding was based on values for women in the government actuary’s department life tables of England and Wales for the years 1998-2008.11

Clinical assumptions and adverse events

The lifespan of Mirena is assumed to be five years.11 If successful, treatment is repeated at five years. Treatment failure with Mirena is assumed to be more evident in the first year.12 13 We also assumed a 2% rate of insertion failure, where the procedure is repeated within a month.13 If Mirena is unsuccessful, women move to the second generation endometrial ablation as indicated by the pathway. No adverse events associated with Mirena were available in the literature.6 7

For first generation endometrial ablation techniques and hysterectomy we used large national audits of both as sources for perioperative and severe postoperative adverse events (table 2).14 5 Minor postoperative complications were not modelled. For second generation endometrial ablation techniques, we used complication rates of microwave endometrial ablation.15

Table 2

 Data used in model to determine cost effectiveness of different treatments for heavy menstrual bleeding

View this table:

Some of the data, specifically proportions in various health states at points in time after initial treatment, related to model outputs rather than model inputs. We applied a method that can be called “probabilistic calibration,” whereby model inputs for the relevant parameters were sampled uniformly across the plausible range and cost and QALY outcomes were weighted according to the likelihood function comparing the model proportions in the various health states with the data.

A repeated intervention is assumed to indicate a failure in the initial procedure. The failure rate for endometrial ablation is about 25-35%, inferred from the number of repeat ablations and hysterectomies that are carried out. This estimate does not include women who return to their general practitioner for medical treatment.7 We assumed that if endometrial ablation of any type fails, repeat ablation (with first generation devices only) or hysterectomy would be offered. In the model it is assumed that 60% of those with recurrent heavy menstrual bleeding (symptomatic state) will have a repeat endometrial ablation and 40% will have a hysterectomy.16 Only one repeat ablation is offered. We further assumed that if the treatment fails a second time, only hysterectomy is available. Complication rates for repeat ablations are assumed to be double those incurred for the initial ablation.17 We assumed that if symptoms do not recur within two years of the initial ablation, then they are unlikely to do so later, and therefore no repeat procedure takes place thereafter. Thus we have limited the time as to when a repeat procedure, ablation, or hysterectomy can occur to two years.

The transition probability for requiring a repeat procedure is time dependent and is reduced by a constant factor each month. This reflects a decreasing hazard, which is obvious from the individual patient data.7

We obtained information on perioperative and severe postoperative adverse events with first generation endometrial ablation techniques from the MISTLETOE study.14 For second generation techniques, we used complication rates with microwave endometrial ablation as a proxy15 because the complication rates from MISTLETOE for the second generation techniques refer to slightly outdated procedures and are no longer relevant. In using the complication rates with microwave endometrial ablation from the study by Parkin et al15 (n=1400), we acknowledge that the true incidence of complications might be underestimated. All data reported in this study were from a specialist centre and reported complication rates might not be representative of other second generation techniques.

Resource use and costs

All costs in the model are in UK £ (2008 value). We used appropriate indices to inflate some of the costs that were obtained from the literature.18 Table 3 shows the costs discounted at 3.5% a year (as per NICE guidelines).8

Table 3

 Costs associated with treatment for heavy menstrual bleeding in UK £ at 2008 prices

View this table:

The source for the costs of adverse events was NHS 2009 reference costs.19 We used the same cost for perioperative and severe postoperative complications for each of the procedures included in the model. The varying severity of complications of the two different types of endometrial ablations and hysterectomy is also reflected in costs.

Utility values

Published sources were used to identify the quality of life weightings associated with each state in the model.13 20 21 Table 4 describes these values in detail.

Table 4

 Health state utilities used in model to determine cost effectiveness of different treatments for heavy menstrual bleeding

View this table:

The quality of life data show that heavy menstrual bleeding is associated with a quality of life value of 0.50, which means that women who have this condition have reported that they feel a loss in terms of quality of life value that is equivalent to half a year at full health. If women have a successful first generation ablation they move to the “well” state associated with a quality of life value of 0.73.21 In contrast, after a successful second generation ablation, women move to the “well” state associated with a quality of life value of 0.84. This is an assumption made in the absence of available data, but relates to the same “well” state as after successful experience with Mirena. This was based on the fact that, if they are successful, second generation techniques (generally speaking) perform better, are less invasive, and have fewer adverse events.7 If ablations of any type are unsuccessful and a repeat ablation is required, however, they are always first generation ablations and the associated quality of life value is 0.73.

The quality of life value for convalescence after hysterectomy is estimated at 0.74.20 22 We assume that this quality of life is not reached until one week after hysterectomy and assumed a zero quality of life value for the week immediately after the operation. This gives an average quality of life over the month of 0.56. After a successful hysterectomy, women move to the “well” state associated with a quality of life value of 0.88.13

For costs, we aggregated according to the distributions at the start of each cycle. This is necessary to account for the full costs of initial treatment.

Analysis

All analyses are carried out from the perspective of the UK NHS and are reported in terms of incremental cost effectiveness ratios presented in terms of cost per quality adjusted life year (QALY). Dominance in the results will exist if one strategy is found to be both cheaper and more effective in terms of producing more QALYs.

We assessed uncertainty in the model parameters through probabilistic sensitivity analysis. In its most common form, this assigns to each input parameter a specific distribution and, by drawing randomly from those distributions, generates a large number of estimates of mean cost and effectiveness. These estimates are then used to form an empirical joint distribution of the differences in cost and effectiveness between interventions.23 24

We carried out one subgroup analysis and two alternative one way deterministic sensitivity analyses. The subgroup analysis was carried out on the basis of the length of the uterine cavity, on the rationale that ablation (as opposed to hysterectomy) is more likely to be successful in women with a shorter cavity.7

In the first deterministic sensitivity analysis we changed utilities from the base case, in which the mean utility values are used, to an analysis based on reported median values from the study by Sculpher20 (table 4). Use of the mean scores is most appropriate in economic evaluation because if outliers are ignored it could lead to the cost effectiveness analysis underestimating costs or overestimating effects. Other published studies used median values reported by Sculpher,20 and not means, without explanation or justification. We believe this use to be inappropriate and are unclear how the medians were estimated.9 In the second deterministic sensitivity analysis we used the “median” quality of life values from Sculpher20 and set the quality of life value for the “well” state after the intervention to the same value for both ablation strategies and Mirena (0.90).

Results

Table 5 presents a summary of the deterministic results. The results show that the strategy that uses first generation endometrial ablation as the first intervention of the pathway is dominated by all the other strategies as it is both more expensive and less effective in terms of producing QALYs. The strategy that adopts hysterectomy as the first and only intervention produces the most QALYs. In comparison with the strategy that uses Mirena first, hysterectomy is more expensive but generates more QALYs. The incremental cost effectiveness ratio (ICER) representing the value of the additional benefit of the hysterectomy strategy compared with Mirena is £1440 (€1633, $2350) per additional QALY. The hysterectomy strategy also produces more QALYs than the second generation endometrial ablation strategy and the estimated incremental cost effectiveness ratio for this comparison is £970 per additional QALY.

Table 5

 Summary of deterministic base case, subgroup, and sensitivity analyses of model to determine cost effectiveness of different treatments for heavy menstrual bleeding

View this table:

The Mirena strategy dominates the first generation endometrial ablation strategy, being cheaper and more effective in producing QALYs. But though it is also cheaper than second generation endometrial ablation, in this comparison it produces fewer QALYs. The incremental cost effectiveness ratio for the second generation endometrial ablation versus Mirena is £2980 per additional QALY.

Figure 2 shows the result of the probabilistic sensitivity analysis. Detailed interpretation of this analysis and additional value of information analysis is presented elsewhere.6 Briefly, it shows the probability that the preferred option is cost effective for any given threshold incremental cost effectiveness ratio for all but a few replications—and the few account for a negligible probability. Mirena was the least costly option and, for low acceptable threshold incremental cost effectiveness ratios, Mirena is preferred with certainty within this model given its assumptions. But as the threshold incremental cost effectiveness ratio increases hysterectomy becomes the preferred option.

Figure2

Fig 2 Cost effectiveness acceptability frontier, showing probability that preferred option is cost effective (ICER=incremental cost effectiveness ratio)

In some replications of the model (accounting for 20% of the probability), hysterectomy was not the most effective option (in terms of total number of QALYs). At an incremental cost effectiveness ratio of £1440, the preferred option changes from Mirena to hysterectomy, so there is a discontinuity in the cost effectiveness acceptability curve.

In the subgroup analysis, carried out to explore the impact of the length of the uterine cavity on cost effectiveness of the alternative interventions for heavy menstrual bleeding, we carried out two separate analyses and a corresponding probabilistic sensitivity analysis. The results of the subgroup analysis showed a small effect of shorter and longer uterine cavity length, which was in the same direction for both. For both cases the results moved slightly so that first generation ablation was no longer “dominated” by hysterectomy and the incremental cost per additional QALY of hysterectomy compared with other strategies was slightly higher (less favourable) than in the base case. There is, however, unlikely to be a change in the decision based on these results and hysterectomy remains the preferred strategy. The results of the probabilistic sensitivity analysis reinforced the results of this deterministic subgroup analysis and are not presented.

In a further deterministic sensitivity analysis, we changed the utilities from the base case in which the mean utility values are used, to reported median values. In the first deterministic sensitivity analysis we used the “median” quality of life values from Sculpher20 and assumed the quality of life scores as a result of first and second generation ablation were equal based on median values (well after first or second generation endometrial ablation 0.90). The key change in results compared with the base case is that there is a clear shift away from the hysterectomy strategy in favour of second generation endometrial ablation. This dominates first generation endometrial ablation as before, but now also dominates hysterectomy. Meanwhile, in this sensitivity analysis the incremental cost effectiveness ratio for second generation endometrial ablation versus the Mirena strategy was £1000 per additional QALY.

The results of the second deterministic sensitivity analysis are similar to those presented in the first. Once again the strategy of second generation endometrial ablation dominates first generation endometrial ablation and hysterectomy, in contrast with the base case. The incremental cost effectiveness ratio for second generation endometrial ablation versus Mirena is £3624 per additional QALY.

Figures 3 and 4 summarise and compare the key findings from changing the utility values (presented in the first and second sensitivity analyses) with the base case . Figure 3 shows that with baseline (mean) utilities, Mirena is the least costly strategy and hysterectomy the most effective. The strategy that starts with first generation endometrial ablation is simply dominated by all of the other strategies. The strategy that starts with second generation endometrial ablation is excluded by extended dominance between Mirena and hysterectomy.

Figure3

Fig 3 Base case deterministic results of cost effectiveness of different treatments for heavy menstrual bleeding (Mirena, hysterectomy, and first and second generation ablation techniques)

Figure4

Fig 4 Deterministic sensitivity analysis with median utility values instead of means for cost effectiveness of different treatments for heavy menstrual bleeding (Mirena, hysterectomy, and first and second generation ablation techniques)

Figure 4 shows the same costs for all strategies as figure 3 but the total QALYs are increased. By using the median utility values, second generation ablation now becomes the most effective strategy: both first generation endometrial ablation and hysterectomy are simply dominated by second generation endometrial ablation.

Discussion

Statement of principal findings

The results of the base case analysis show that hysterectomy is the preferred strategy as the first intervention for heavy menstrual bleeding. Hysterectomy dominates the strategy that uses first generation endometrial ablation as the initial intervention. Although hysterectomy is more expensive, it produces more QALYs relative to other remaining strategies and is likely to be considered cost effective: the incremental cost effectiveness ratio for hysterectomy compared with Mirena is £1440 per additional QALY. These results suggest that hysterectomy first would be considered the preferred strategy in light of the acceptable thresholds used by NICE, which tends to accept new technologies if the incremental cost effectiveness ratio is within £20 000 per additional QALY.

Our main results suggesting the relative cost effectiveness of hysterectomy were robust to all the sensitivity and subgroup analyses, with the exception of the sensitivity analysis carried out on the utility data. This was based on an analysis that used the reported values of utilities that are available in the published literature, specifically the “mean”’ reported utility values, which is appropriate.25 26

Strengths and limitations

The major strength of the economic component of this study is that it is based on a sophisticated Markov model, which was informed by data from an individual patient level data meta-analysis of randomised trials. A multidisciplinary team including economists, expert clinicians, and statisticians provided input into the model structure primarily based on the evidence in the literature. All assumptions used in the model were based on the available evidence as far as possible. All required assumptions were agreed with the team before the analysis was carried out and without knowledge of how these assumptions might affect the results.

In terms of limitations, it is possible that we did not include all aspects of costs and outcome as the utilities used are likely to reflect the satisfaction of the outcomes only. Once women have had a hysterectomy, for example, their satisfaction is high because, in contrast with the other interventions, they experience no bleeding at all. But the utility measure does not capture the anxiety before hysterectomy associated with major surgery and general anaesthetic. Such anxieties can lead to decisions that avoid major surgery as a first step and to try other less invasive options for as long as possible. The perspective of the analysis does not include the costs to women associated with six to eight weeks’ convalescence after hysterectomy. Furthermore, the model’s time horizon and the lack of long term data exclude possible effects of long term complications such as urinary stress incontinence for which surgery is required.27

Strengths, weaknesses, and assumptions in relation to other studies

With regard to the utility values that have been used in the current study the following points are worth noting. First, the paper by Sculpher20 has been extensively referenced in the literature. Other studies, including that by Garside et al,9 have used the median values from that paper and not the means, seemingly without justification or a critique of the face validity of these data. Furthermore, for economic evaluation it is the mean values that are most appropriate to use as it is considered important to capture outliers to avoid underestimating costs or overestimating benefits.25 26

Our results suggest that hysterectomy is the most cost effective strategy, but we must emphasise the uncertainty in the utility data. Mirena has not been extensively evaluated, and there are only limited data available on long term follow-up.7

Comparison with other studies

The results of the model based economic evaluation reported by Garside et al also showed hysterectomy was the most cost effective strategy for treating heavy menstrual bleeding.9 They compared second generation with first generation ablative techniques and hysterectomy. Mirena was not included in their comparative analysis. When compared with hysterectomy, second generation ablative techniques were found to be less costly but also provided fewer QALYs. The authors used median, not mean, utility values in their analysis but without justification. They reported that the results of their model were highly sensitive to the utility values associated with being well after ablation and recommended that results are interpreted with caution because of this sensitivity.9 In our sensitivity analysis, when we used the same median value for the utilities, as opposed to the means, the results showed that second generation endometrial ablation was the most cost effective strategy.

Our results do not concur with the result of the Finnish trial by Hurskainen et al, which compared Mirena with hysterectomy and found Mirena to be cost effective at five years.13 There was no significant difference in quality of life scores at five years, as measured by the EQ-5D instrument, between the two treatment groups. But this is unsurprising as 40% of women in the Mirena arm went on to have a hysterectomy and completed EQ-5D at the end of treatment.13 It is also a cause for concern that mean direct costs in the Mirena arm remained significantly lower ($1892) than the hysterectomy arm ($2787), despite the substantial number subsequently undergoing hysterectomy.

An economic modelling study undertaken to inform NICE guidelines8 suggested that Mirena is cost effective when compared with both hormonal and non-hormonal treatment. Mirena generated more QALYs at a lower cost than any other medical or surgical treatment strategy considered. Our model differed from the NICE model in terms of the assumptions. The NICE model assumed that within the five year lifespan of Mirena, some women who experienced failure with Mirena would move straight to hysterectomy (based on data from Hurskainen et al13). In contrast, in our study, our assumption (based on advice from clinical colleagues) was that all women who experienced failure with the Mirena strategy would, in the first instance, follow the second generation endometrial ablation pathway. This helps to explain the difference in results and the relative preference in our analysis for hysterectomy over Mirena. Furthermore, it also highlights the importance of hysterectomy, as integral to NICE guidance supporting Mirena in the first instance is the belief that hysterectomy is available if Mirena fails.

An implicit assumption in this and other similar studies is that there exists equivalent ability to undertake all these procedures both from a time and skill base, but this is unlikely to be true. For example, Mirena can be fitted in primary care; second generation ablative techniques, while requiring use of a hospital, can be carried out by specialist after minimal training in an outpatient setting; but hysterectomy can be undertaken only by more highly trained specialists in inpatient theatre suites. While these differences are reflected in the costs of the procedures used in the analyses, constraints in available capacity and skills are not.

Implications

Our results suggest that, based on current best available data, which are limited, Mirena is not a robust cost effective strategy compared with hysterectomy. These results contradict current opinion and practice in gynaecology, which has seen a reduction in the rate of hysterectomy for heavy menstrual bleeding over the past decade or so. Our evaluation is based on the best available data and the assumptions used in the model were made before the analysis and are unbiased. The data, however, might not reflect the decision making process between women and doctors for whom minimal risks and relatively quick and convenient treatments might offset the higher failure rates associated with Mirena initially, knowing that a more definitive treatment is still available. This leads to a potential conflict between an individual approach based on choice and a utilitarian one based on maximising gains for society.

Unanswered questions for future research

We used a sophisticated model, data from an individual patient data meta-analysis, and all available data on quality of life associated with the available interventions for the outcomes for alternative treatments for heavy menstrual bleeding.

One of the main causes of uncertainty is with regard to the utility values associated with alternative interventions and their success. There would be little value in future studies comparing the outcomes and costs of any alternative interventions to treat women for heavy menstrual bleeding without undertaking a comprehensive study to clarify the quality of life associated with the outcomes of the alternative interventions.

Our results show that more robust clinical data would enhance clinical decision making, in particular with regard to interventions such as Mirena, for which there are limited follow-up data. Some of the current authors are involved in the Birmingham based ECLIPSE trial, which is a large UK funded (NCCHTA) trial that will provide evidence on whether Mirena is preferable to standard oral treatments for heavy menstrual bleeding. Several approaches to assessing quality of life issues and preferences are currently being considered.

Preferences of women and clinicians will continue to be extremely influential in decision making. Many clinicians believe that a “one size fits all” approach to the treatment of heavy menstrual bleeding is impossible. As individual choices can determine perceived success, eliciting preferences is also extremely relevant in this context.28

What is already known on this topic

  • Less invasive alternatives to hysterectomy for the treatment of heavy menstrual bleeding, such as endometrial ablation and Mirena, have become increasing popular

  • As second generation endometrial ablation techniques and Mirena are cheaper and less invasive, they are likely to be preferred to hysterectomy

What this study adds

  • Second generation non-hysteroscopic endometrial ablation and Mirena are both less costly and produce more QALYS than first generation techniques

  • Based on current best available evidence Mirena is not a cost effective strategy compared with hysterectomy

  • Based on all available evidence on effectiveness, cost, and utility values, hysterectomy produces cost effectiveness ratios that are likely to be accepted by decision makers

Notes

Cite this as: BMJ 2011;342:d2202

Footnotes

  • Contributors: TER, PB, SB, and JD contributed to the design of the whole project and obtained funding. TER and PB designed the model based cost effectiveness analysis. TER prepared the manuscript as lead writer. AT under the supervision of PB constructed the model with advice from KC and SB. AT under the supervision of TER and PB identified and collected the required data on costs and effectiveness for the model and carried out the analysis. LM, JD, KC, RC, and SB provided the relevant data from the individual patient data meta-analysis. TR, PB, and AT interpreted the results with assistance from KC and SB. TR is guarantor.

  • Funding: This study was funded by the National Institute for Health Research Health Technology Assessment Programme (05/45/02).

  • Competing interests: All authors have completed the Unified Competing Interest form at www.icmje.org/coi_disclosure.pdf (available on request from the corresponding author) and declare: no support from any organisation for the submitted work; no financial relationships with any organisations that might have an interest in the submitted work in the previous three years; no other relationships or activities that could appear to have influenced the submitted work.

  • Ethical approval: Not required.

  • Data sharing: No additional data available.

This is an open-access article distributed under the terms of the Creative Commons Attribution Non-commercial License, which permits use, distribution, and reproduction in any medium, provided the original work is properly cited, the use is non commercial and is otherwise in compliance with the license. See: http://creativecommons.org/licenses/by-nc/2.0/ and http://creativecommons.org/licenses/by-nc/2.0/legalcode.

References

View Abstract