Two-year results and subgroup analyses of the PEPCAD China in-stent restenosis trial: A prospective, multicenter, randomized trial for the treatment of drug-eluting stent in-stent restenosis

Catheter Cardiovasc Interv. 2016 Mar:87 Suppl 1:624-9. doi: 10.1002/ccd.26401. Epub 2016 Jan 17.

Abstract

Background: The PEPCAD China ISR trial investigated the safety and efficacy of paclitaxel-coated balloon (PCB) angioplasty in an Asian patient population with coronary drug-eluting stent in-stent restenosis (DES-ISR).

Methods: A total of 220 patients with coronary DES-ISR were treated with PCB angioplasty or with paclitaxel-eluting stents (PES). This randomized (1:1), single-blind prospective multicenter trial in a Chinese population used 9-month in-segment late lumen loss (LLL) as the primary endpoint. Secondary endpoints included the 24-month clinical event rates.

Results: Both treatment groups were similar in terms of patient, lesion, or procedural characteristics. After the 12-month follow-up evaluation, additional clinical events only occurred in the PES study group. The combined rate of all-cause mortality and myocardial infarction (MI) in the PCB group was significantly lower than that in the PES group (3.7% vs. 11.8%, P = 0.03). Additional subgroup analyses of 9-month in-segment LLL and 2-year target lesion failure in patients with diabetes, small vessels, diffuse ISR, and stent margin restenosis did not show more favorable results for one specific treatment group.

Conclusions: The 2-year follow-up demonstrated sustained long-term clinical efficacy for both devices. PCB angioplasty was associated with significantly lower overall and cardiovascular mortality/MI rates in patients with DES-ISR lesions while avoiding the use of additional metal layers for drug release (ClinicalTrials.gov identifier: NCT 01622075).

Trial registration: ClinicalTrials.gov NCT01622075.

Keywords: drug-eluting stent; in-stent restenosis; paclitaxel-coated balloon; paclitaxel-eluting stents.

Publication types

  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Angioplasty, Balloon, Coronary / adverse effects
  • Angioplasty, Balloon, Coronary / instrumentation*
  • Angioplasty, Balloon, Coronary / mortality
  • Cardiac Catheters*
  • Cardiovascular Agents / administration & dosage*
  • China
  • Coated Materials, Biocompatible*
  • Coronary Artery Disease / diagnostic imaging
  • Coronary Artery Disease / mortality
  • Coronary Artery Disease / therapy*
  • Coronary Restenosis / diagnostic imaging
  • Coronary Restenosis / etiology
  • Coronary Restenosis / mortality
  • Coronary Restenosis / therapy*
  • Drug-Eluting Stents*
  • Humans
  • Myocardial Infarction / etiology
  • Paclitaxel / administration & dosage*
  • Percutaneous Coronary Intervention / adverse effects*
  • Percutaneous Coronary Intervention / instrumentation*
  • Percutaneous Coronary Intervention / mortality
  • Prospective Studies
  • Prosthesis Design
  • Risk Factors
  • Single-Blind Method
  • Time Factors
  • Treatment Outcome

Substances

  • Cardiovascular Agents
  • Coated Materials, Biocompatible
  • Paclitaxel

Associated data

  • ClinicalTrials.gov/NCT01622075