The extensile rectus snip exposure in revision of total knee arthroplasty

J Bone Joint Surg Br. 2003 Nov;85(8):1120-2. doi: 10.1302/0301-620x.85b8.14214.

Abstract

Revision of a total knee arthroplasty may require an extensile approach to permit a satisfactory exposure without compromising the attachment of the patellar tendon. It has been assumed that a rectus snip is a relatively benign form of release, but the effect of using this approach on function, pain and patient satisfaction is not known. From January 1997 to December 1999, 107 patients who underwent revision of total knee arthroplasty were followed up at a minimum of two years (mean 40.5 months) and assessed by the Oxford Hip Score, the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the Short-Form (SF)-12 and patient satisfaction. Co-morbidity, surgical exposure, the Hospital for Special Surgery (HSS) knee scores and the range of movement were also used. A standard medial parapatellar approach was used in 57 patients and the rectus snip in 50. The two groups were equivalent for age, sex and co-morbidity scores. The WOMAC function, pain, stiffness and satisfaction scores demonstrated no statistical difference. The use of a rectus snip as an extensile procedure has no effect on outcome.

Publication types

  • Evaluation Study

MeSH terms

  • Arthroplasty, Replacement, Knee / methods*
  • Arthroplasty, Replacement, Knee / rehabilitation
  • Female
  • Follow-Up Studies
  • Health Status Indicators
  • Humans
  • Knee Joint / physiopathology
  • Male
  • Muscle, Skeletal / surgery*
  • Patient Satisfaction
  • Prosthesis Failure*
  • Range of Motion, Articular
  • Reoperation
  • Treatment Outcome