Skip to main content
  • Research article
  • Open access
  • Published:

On the alert: future priorities for alerts in clinical decision support for computerized physician order entry identified from a European workshop

An Erratum to this article was published on 05 November 2013

Abstract

Background

Clinical decision support (CDS) for electronic prescribing systems (computerized physician order entry) should help prescribers in the safe and rational use of medicines. However, the best ways to alert users to unsafe or irrational prescribing are uncertain. Specifically, CDS systems may generate too many alerts, producing unwelcome distractions for prescribers, or too few alerts running the risk of overlooking possible harms. Obtaining the right balance of alerting to adequately improve patient safety should be a priority.

Methods

A workshop funded through the European Regional Development Fund was convened by the University Hospitals Birmingham NHS Foundation Trust to assess current knowledge on alerts in CDS and to reach a consensus on a future research agenda on this topic. Leading European researchers in CDS and alerts in electronic prescribing systems were invited to the workshop.

Results

We identified important knowledge gaps and suggest research priorities including (1) the need to determine the optimal sensitivity and specificity of alerts; (2) whether adaptation to the environment or characteristics of the user may improve alerts; and (3) whether modifying the timing and number of alerts will lead to improvements. We have also discussed the challenges and benefits of using naturalistic or experimental studies in the evaluation of alerts and suggested appropriate outcome measures.

Conclusions

We have identified critical problems in CDS, which should help to guide priorities in research to evaluate alerts. It is hoped that this will spark the next generation of novel research from which practical steps can be taken to implement changes to CDS systems that will ultimately reduce alert fatigue and improve the design of future systems.

Peer Review reports

Background

Computerized physician order entry and clinical decision support

Computerized physician (or provider) order entry (CPOE) systems allow users to prescribe using a computer system, reducing the risk of prescribing errors resulting from illegible handwriting or transcription errors. They have also been shown to reduce medication errors and adverse drug reactions in hospitals [16], although large multi-centred trials, which give ‘guidance in optimizing CPOE implementations’ are lacking [7]. CPOE systems can have integrated clinical decision support (CDS), which attempts to improve clinicians’ decisions through guidance, alerts, and reminders. These CDS systems draw on information contained in supporting knowledge database(s), which are often integrated with software algorithms that generate alerts during drug prescribing [8, 9] and may also address issues relevant for the administration process [10]. In principle, clinicians support the idea of CDS alerts in identifying and preventing erroneous or less optimal prescribing [1114].

Alert specificity and sensitivity

In a CDS system, sensitivity is the ability of the system to alert prescribers correctly when patients are at risk of experiencing drug-induced harm, for example, from a drug–drug interaction or drug allergy. The specificity of the CDS system is a measure of its ability to distinguish between events that put an individual at risk of harm and non-events that will not: the more false positives, the lower the specificity. Previous research has led to the suggestion that safe alerting systems should have high specificity and sensitivity, present clear information, not unnecessarily disrupt workflow, and facilitate safe and efficient handling of alerts [15]. Indeed, the ideal alert should demonstrate the following characteristics: provision of the right (correct) information, to the right person, in the right CDS intervention format, through the right channel, and at the right time in the workflow [16]. These 'five rights' may be better achieved when alerts are tailored and filtered to take into account the characteristics of (1) the organizational unit and the user, (2) the patient or case, and (3) the alert [17].

Knowledge of alert fatigue in CDS systems

CDS alerts have the potential to cause harm to patients by occurring too frequently and thus producing distracting ‘noise’ in the system [1114]. In most, if not all, systems a large proportion of alerts generated by CDS is overridden (i.e. clinician chooses to proceed without adjusting or cancelling the prescription) [10, 15, 18, 19]. This may be a symptom of ‘alert fatigue’, the mental state resulting from alerts consuming too much time and mental energy, which may increase the chance that future alerts pertinent to patient safety will be overridden [2022] along with clinically irrelevant ones [23]. In general terms, exposure to frequent false alarms can desensitize users so that they ignore and increasingly mistrust alarms [24].

Most of the focus on reducing override rates in CDS systems considers strategies such as the customization of third party providers’ sets of alerts [2528], implementation of highly specific algorithms [18], and use of tiered severity grading to stratify and reduce the number of interruptive alerts [29, 30]. Other suggested strategies to counteract alert fatigue have included turning off frequently overridden alerts and directing time-dependent drug–drug interaction alerts to nurses [31, 32]. A formal framework to evaluate the appropriateness of alerts may also prove useful [33].

Alert fatigue continues to plague and frustrate users despite varying improvement strategies [34] and the overall effect and generalizability of such strategies on patient safety is unclear. Indeed, in many European countries, hospital electronic prescribing systems are in the embryonic stages, and vary widely in terms of their use and how they are being both developed and implemented. Therefore, the need for further research in the use of alerts in CDS systems remains. To address these issues, European experts on CDS attended a workshop in Birmingham, United Kingdom. Here, we describe the agreed consensus from the workshop on the current gaps in the research, the challenges of improving alerting in CDS systems, and the issues that were as yet unanswered. Recommendations are also provided for the strategic direction of future research on CDS-based safety alerts from a European perspective.

Methods

Researchers with a strong publication record in the field of CDS were identified through literature searches and were invited by email to attend a two-day workshop in Birmingham, United Kingdom, in November 2011 on “building research capacity in the study of alerts in CDS systems”. The workshop was funded by the European Regional Development Fund and organized by the University Hospitals Birmingham NHS Foundation Trust. No ethical approval was required for this work. The objectives of the workshop were (1) to identify key knowledge gaps in the study of CDS-based alerting; (2) to identify research priorities on CDS-based alerting; and (3) to identify research methodologies to evaluate alerts.

Workshop participants (see online Additional file 1) separated into smaller groups for directed discussions after a general discussion of previous work on the nature of alert fatigue in CPOE and in other industries. Research questions to answer the objectives were discussed in each smaller participants group (N=4–6 participants) first, and then summarized in the plenum. All participants provided full consent for the recording of discussions. Minutes from the discussions were transcribed and circulated among the group for approval following the workshop. The main themes highlighted and discussed at the workshop were abstracted, and further sub-themes identified. All participants were requested to comment on various iterative drafts and their comments are incorporated into this paper. The following report reflects the discussions and recommendations of the expert participants, with additional contributions from an invitee who was unable to attend.

Results

Knowledge gaps in the study of alerts in CDS systems

The workshop participants identified knowledge gaps in the study of alerts in CDS systems that require further investigation (Table 1).

Table 1 Identified knowledge gaps in the research on CDS alerts

Important research priorities

The following four priorities for research on alerts in CDS systems have been developed from the gaps in knowledge identified in Table 1. As time was limited, the workshop did not assign research priorities to all areas where gaps in knowledge were identified.

Determine the optimum sensitivity and specificity of a CDS system in practice

We agreed that the perfect CDS system would be both 100% sensitive and 100% specific. Indeed clinicians will wish the overall sensitivity and specificity to be high; that is, will wish to know all those patients who will in fact experience drug-induced harm, and none of those who will suffer no harm (whether or not they are at risk). Current systems tend to have high sensitivity but often the specificity is low [38]. Sensitivities below 100% are risky and may contribute to patient harm, especially for the most injurious events. If we strive for high sensitivity, we will inevitably increase the number of alerts. Should we instead be looking for better specificity?

It is important that the system is able to draw in additional information from beyond the knowledge base – by which we mean the collection of evidence-based information about drugs and their interactions – to increase specificity, for example through the integration of individual patient information such as laboratory values and co-morbidities with information on medicines [3942]. The challenge is in ensuring that drug information is accurate, comprehensive and up-to-date, whilst keeping the process manageable in terms of expertise, time, and resources. One solution may be the collaborative development and sharing of knowledge bases between countries [9, 43]. Indeed, national knowledge bases exist, such as the Dutch national drug database (G-Standaard), which serves as a professional standard for pharmacists in the Netherlands, and is the standard from which all Dutch CPOE systems are based [44]. Sharing of such knowledge bases may enable the effective use of resources and harnessing of expertise.

However, recent findings suggest that systems can be both sensitive and specific, or indeed lack both qualities [45]. Furthermore, system quality may differ with regards to different alert categories (e.g. overdose vs. drug–drug interactions), and differences when alerting for medications only, as opposed to a combination of medication and patient parameters [45, 46]. Future studies involving rigorous testing, alongside more in-depth analysis of system design features leading to high sensitivity and specificity, can be used to guide future CPOE system designs in order to determine the optimum sensitivity and specificity in the real world. By comparing differences in the design of current systems, it may be possible to identify a gold standard on which to base future CPOE systems.

Research from other industries may help guide discussions on the appropriate balance between specificity and sensitivity. A meta-analysis identified experimental studies that compared human performance aided by imperfect diagnostic automation with unaided human performance detecting the same signals — when sensitivity of automated alerts fell below 70%, performance was worse than in the absence of automation [47]. This is a rough estimate (95% confidence interval = 56–84%), but it suggests that automated systems require the sensitivity of alerts to be over some minimum value if they are to be beneficial. Indeed, this apparently counter-intuitive finding that poor CDS is worse than no CDS emphasizes the dangers of systems that miss important signals.

Determine whether personalization of alerts will reduce alert fatigue

Certainly, the importance of applying human factors principles to matters such as placement, visibility, prioritization, and colour in the design of CDS alerts is well established [4850]. Customization to the setting in which the system is used (the ‘use environment’) could provide an opportunity to eliminate inappropriate alerts and requires further evaluation. For example, an interaction warning for excessive sedation by a benzodiazepine/opioid combination is rather meaningless in anaesthetized patients. Hence, such alerts would be suppressed in the “operating theatre” but not in “general practice”.

Allowing individual users to personalize the interface design of CDS alerts may also reduce alert fatigue. Indeed, CDS system developers can learn a lot from smartphones, which allow for the personalization of their user interface (e.g. alter icon arrangement, font size, or background colour). Most smartphone users enjoy the ability to modify their devices in certain ways. Conversely, we agreed that CDS alerts are often boring, difficult to see and understand, and thus frustrating to users. In addition, we discussed that CDS alerts often result in negative feeling in users, for example, because their clinical decision making has been criticized. Determining whether cosmetic personalization improves usability and receptivity of CDS alerts is important and should be investigated.

Personalization of alerts may not just be limited to the user interface, but may be done in an automatic way based upon a user’s familiarity with certain risk situations, training, and expertise. For example, frequent users may require fewer alerts than those who rarely use a system or a specific medicine. The development of individualized alerts will require structured and systematic design to ensure that they are generated appropriately for each patient. Allowing an individual prescriber to have control over which alerts are switched on or off may have some benefit, but could introduce the potential for error due to slips or lapses [51], particularly when a clinician is busy or distracted. Determining whether personalization in this way improves usability and receptivity of CDS alerts is important.

Alerts are only valuable if they may change the patient’s clinical management. Those that are irrelevant to clinical management add to the alert burden without any clinical benefit. Studies to identify and refine management decision support will be important.

Determine whether appropriate timing of an alert within the prescribing process will reduce alert fatigue

We agreed that ideally alerts should be displayed as early as possible in the prescribing process, and if possible, there should be no more than one alert for any prescription (by which we mean, an order for a single item). So, for example, if a situation exists that would strictly contraindicate a prescription (such as a clinically relevant allergy alert) users should be alerted before they have gone too far down the prescribing path. However, there are difficulties in a system set up to show only one alert for one drug prescription. For example, the user may have to enter all necessary information (e.g. dose, route, frequency and duration) before an overarching CDS alert relevant to all elements of the prescription is shown. Alerting the user as early as possible and having complete information that can be integrated into a single CDS alert are not easily compatible. We discussed a hierarchy of agreed alerts, that is, a grading such as (i) prescribing absolutely contraindicated; (ii) prescribe but only if certain conditions are met; and (iii) prescribe where benefit outweighs harm. Such a hierarchy would mitigate this conflict, since an alert at the highest level that interrupted the process could be displayed as soon as it was first encountered. However, this may be difficult to achieve in practice. Indeed, depending on the user interface of the computerized system, one alert per item may not be practicable. For example, when prescriptions for multiple drug items can be entered all together it could be difficult to determine which alert should be selected with priority. New research should focus on assessing the impact of the timing and number of alerts generated during one drug prescription.

Determine the relevance of the outcome measures in evaluating alerts

One of the main challenges in designing and evaluating alerts is deciding on what outcome measure(s) should be used. Here we suggest potential measures (Table 2).

Table 2 Potential outcome measures for the evaluation of alerts in CDS

Although several outcome measures exist, those that are obviously relevant such as mortality, are unlikely, because of their rarity, to give a full or reliable picture of the value of alerts; and those which are more common are less obviously relevant. The correct balance needs to be established. There is also a need for consistent definitions of medication error and therapeutic harm [53] in order to increase the comparability of studies [54].

Research methods to evaluate alerts

The appropriate research methods for evaluating alerts depend on the research question being asked. Here we consider methods that would be of potential use in evaluating alerts in CDS and for addressing the priorities for research identified during the workshop.

Expert opinion

Expert opinion has been previously used to try to evaluate alerts and potentially improve the quality of alerting. For example, groups of clinicians have been asked to agree on which alerts could be turned off safely within a hospital system [32] and to assess the value of alerts for 120 drug–drug interactions [55]. This method has also been used to identify and refine high-severity drug–drug interactions [56] and to identify low-priority drug–drug interactions that do not require interruptive alerts [57]. These studies may provide information on some research gaps, such as determining which outcome is most relevant to the specific research question. An expert panel could be used to examine a large number of prescriptions and see what warnings appear. The panel would select an outcome measure and explore how to reduce the number of warnings, in order to design more specific alert algorithms. A possible increase in alert adherence could then be investigated.

Observational (naturalistic) studies

Naturalistic studies involve the careful observation and recording of behaviours and events in their natural setting and they can be very powerful when based on strong theoretical foundations. Such studies have an important role in the study of alerts in CDS systems and previously have been used to explore factors affecting prescribing errors in hospitals [58]. A possibility for a naturalistic study would be to implement CDS systems in one geographical area or electronic health record system and study the outcome compared with other areas or groups where no system exists. Alternatively, an evaluation of the outcomes pre- and post-introduction of a CDS system in one setting may provide useful information on the effect of CDS alerts. Indeed, a recent controlled trial demonstrated a reduction in the prevalence of potentially dangerous drug–drug interactions, after implementation of a drug–drug interaction database [59]. However, a given CDS system may produce different responses in different healthcare settings [60].

Experimental studies

Experimental studies can allow for the manipulation and testing of CDS alerts in a controlled environment. For example, it would be possible to turn alerts on and off to see the effect on override rates. This could be undertaken in a safe setting that would not have any direct impact on patient care or safety during the experiment. A previous study found that the rates of prescribing errors fell significantly when junior doctors were shown a modal alert – an alert that requires users to interact with it before they can return to the main interface – compared with a non-modal alert [61]. There are few similar studies. They may be the most practicable way to investigate the ideal level of sensitivity and specificity, as well as determining the effects of the personalization of alerts for the user. However, they may not take into account the effect of stressful working environments on the user.

Comparing naturalistic and experimental study designs

Naturalistic studies have the advantage of providing a real-life assessment of alerts and alert overrides. However, removing alerts and monitoring the effect may be problematic and unethical. The effectiveness of such studies is also dependent on having a suitable audit trail and capturing the data reproducibly. Conversely, experimental studies benefit from a controlled environment with no ethical constraints. However, such studies may not reflect real-life use of alerts accurately, as prescribers could alter their use of a CPOE system when they are being watched.

Challenges to implementing research methods

The value of the alert must in part be judged by the actions taken in response to it. This may, however, prove challenging. There is, at present, no easy way to differentiate between an informed decision to override an alert and one that is ignored or missed, although this is a critical distinction. Some systems require a reason for overriding certain alerts – but this adds to the burden on the end user, and only provides reliable feedback to the system developers if the user provides the true reason for overriding.

Both naturalistic and experimental approaches are valuable, but the sequencing of events within the study design is important: the effectiveness of a naturalistic approach depends on having a suitable audit trail and capturing the data reproducibly. Randomization and masking in experimental studies can be difficult in such circumstances [62]. There are also problems with screen capture designs, since in naturalistic settings there are many actions to capture successfully.

It would also be beneficial to work with organizations that are looking to implement CPOE/CDS and monitor the steps to full implementation. Nonetheless, the challenge of how to measure the adverse outcomes prevented or caused by a decision support system remains, and a gold standard defined by an expert group is needed to achieve such measurement. This standard could then be used as a yardstick to judge the system. However, this may only test the system and not the outcome.

An ‘ideal’ design for studies of alerts in CDS systems may not exist. One of the approaches could be a purposeful synthesis/integration of different studies leading to new insights. However, one specific study design may provide considerable insight into CDS alerts. This would be to set up a safe environment where alerts that are always overridden are removed from a CDS system. After the alerts are removed, the system is then interrogated to see what happens in terms of override rates and potential patient outcomes. If supported by an expert panel who could assess existing alerts and select those for removal, an iterative prospective study may be valuable.

Discussion

Summary of findings

We have identified several research priorities including (1) the need to determine the optimal sensitivity and specificity of alerts; (2) whether adaptation to the environment or characteristics of the user may improve alerts; and (3) whether modifying the timing and number of alerts improves alerts. We have also discussed the challenges and benefits of using naturalistic or experimental studies in the evaluation of alerts and suggested appropriate outcome measures.

We recommend that the reduction of alert fatigue may be possible through the integration of patient, illness and medicine information, and through the development of an alert hierarchy to generate at most one clinically relevant alert per prescription. Ideally, alerts will only be displayed when there is a true risk of harm, but will always be displayed when such risks exist, to the extent that it is desirable or necessary for the user. Given that no practical system can achieve 100% specificity and 100% sensitivity, the best balance needs to be determined. We believe that specificity can be increased without sacrificing sensitivity through the integration and linkage of solid knowledge bases and patient parameters, using well-tailored algorithms. Future collaboration with researchers and practitioners from other countries, such as the United States, where the use of CDS systems is prominent, is also important. However, this does mean that, even if conclusions can be made about optimal alert generation, it may not be possible to implement universal change within every system in every hospital.

Strengths and limitations of the approach

This workshop successfully facilitated collaboration and communication between researchers, which allowed for the further refinement of research priorities and the generation of future research ideas. Most discussion on CDS has come from the United States [7, 43]; here we have identified and refined the knowledge gaps, particularly relevant to the European market. Workshop participants were experts in the use of CDS, with a wide breadth of knowledge of and experience in using a variety of locally-developed and commercial prescribing systems. However, as a limitation, the majority of participants were academic researchers and we did not consult other potentially relevant groups such as CDS vendors. Time constraints also meant that not every knowledge gap could be expanded upon during the workshop. Furthermore, despite a varied representation of participants from across Europe, this paper cannot, unfortunately, provide a pan-European perspective on alerts in CDS.

Conclusions

The use of CDS systems within CPOE is increasing rapidly and is becoming an essential component of patient care in many countries. Previous research has indicated the need to eliminate alert fatigue, but this has yet to be achieved in practice. Research should be undertaken to determine whether the use of CDS alerts really improves patient outcomes, using appropriate methodologies and appropriate outcome measures. Strategies must be developed to reduce the burden of CDS alerts without compromising patient safety.

References

  1. Ammenwerth E, Schnell-Inderst P, Machan C, Siebert U: The effect of electronic prescribing on medication errors and adverse drug events: a systematic review. J Am Med Inform Assoc. 2008, 15 (5): 585-600. 10.1197/jamia.M2667.

    Article  PubMed  PubMed Central  Google Scholar 

  2. Hug BL, Witkowski DJ, Sox CM, Keohane CA, Seger DL, Yoon C, Matheny ME, Bates DW: Adverse drug event rates in six community hospitals and the potential impact of computerized physician order entry for prevention. J Gen Intern Med. 2010, 25 (1): 31-38. 10.1007/s11606-009-1141-3.

    Article  PubMed  Google Scholar 

  3. Reckmann MH, Westbrook JI, Koh Y, Lo C, Day RO: Does computerized provider order entry reduce prescribing errors for hospital inpatients? A systematic review. J Am Med Inform Assoc. 2009, 16 (5): 613-623. 10.1197/jamia.M3050.

    Article  PubMed  PubMed Central  Google Scholar 

  4. Shamliyan TA, Duval S, Du J, Kane RL: Just what the doctor ordered. Review of the evidence of the impact of computerized physician order entry system on medication errors. Health Serv Res. 2008, 43 (1 Pt 1): 32-53.

    PubMed  PubMed Central  Google Scholar 

  5. van Doormaal JE, van den Bemt PM, Zaal RJ, Egberts AC, Lenderink BW, Kosterink JG, Haaijer-Ruskamp FM, Mol PG: The influence that electronic prescribing has on medication errors and preventable adverse drug events: an interrupted time-series study. J Am Med Inform Assoc. 2009, 16 (6): 816-825. 10.1197/jamia.M3099.

    Article  PubMed  PubMed Central  Google Scholar 

  6. Wolfstadt JI, Gurwitz JH, Field TS, Lee M, Kalkar S, Wu W, Rochon PA: The effect of computerized physician order entry with clinical decision support on the rates of adverse drug events: a systematic review. J Gen Intern Med. 2008, 23 (4): 451-458. 10.1007/s11606-008-0504-5.

    Article  PubMed  PubMed Central  Google Scholar 

  7. Mulherin DP, Zimmerman CR, Chaffee BW: National standards for computerized prescriber order entry and clinical decision support: the case of drug interactions. Am J Health Syst Pharm. 2013, 70 (1): 59-64. 10.2146/ajhp120217.

    Article  PubMed  Google Scholar 

  8. Eiermann B, Bastholm Rahmner P, Korkmaz S, Landberg C, Lilja B, Shemeikka T, Veg A, Wettermark B, Gustafsson LL: Knowledge Bases for Clinical Decision Support in Drug Prescribing – Development, Quality Assurance, Management, Integration, Implementation and Evaluation of Clinical Value. Decision Support Systems. Edited by: Jao CS. 2010, Crotia: InTech

    Google Scholar 

  9. Böttiger Y, Laine K, Andersson ML, Korhonen T, Molin B, Ovesjö ML, Tirkkonen T, Rane A, Gustafsson LL, Eiermann B: SFINX-a drug-drug interaction database designed for clinical decision support systems. Eur J Clin Pharmacol. 2009, 65 (6): 627-633. 10.1007/s00228-008-0612-5.

    Article  PubMed  Google Scholar 

  10. Quinzler R, Schmitt SP, Pritsch M, Kaltschmidt J, Haefeli WE: Substantial reduction of inappropriate tablet splitting with computerised decision support: a prospective intervention study assessing potential benefit and harm. BMC Med Inform Decis Mak. 2009, 9: 30-10.1186/1472-6947-9-30.

    Article  PubMed  PubMed Central  Google Scholar 

  11. Ko Y, Abarca J, Malone DC, Dare DC, Geraets D, Houranieh A, Jones WN, Nichol WP, Schepers GP, Wilhardt M: Practitioners' views on computerized drug-drug interaction alerts in the VA system. J Am Med Inform Assoc. 2007, 14 (1): 56-64.

    Article  PubMed  PubMed Central  Google Scholar 

  12. Ammenwerth E, Jung M: Expectations and barriers versus cxCDSS-CPOE: a European user survey. Proceedings of the PSIP International Workshop, Sofia, Bulgaria, 23 June 2011. Edited by: Beuscart R, Tcharaktchiev D, Angelova G. 2011, Shoumen: Incoma, 49-52.

    Google Scholar 

  13. Lapane KL, Waring ME, Schneider KL, Dubé C, Quilliam BJ: A mixed method study of the merits of e-prescribing drug alerts in primary care. J Gen Intern Med. 2008, 23 (4): 442-446. 10.1007/s11606-008-0505-4.

    Article  PubMed  PubMed Central  Google Scholar 

  14. Weingart SN, Simchowitz B, Shiman L, Brouillard D, Cyrulik A, Davis RB, Isaac T, Massagli M, Morway L, Sands DZ, et al: Clinicians' assessments of electronic medication safety alerts in ambulatory care. Arch Intern Med. 2009, 169 (17): 1627-1632.

    Article  PubMed  Google Scholar 

  15. van der Sijs H, Aarts J, Vulto A, Berg M: Overriding of drug safety alerts in computerized physician order entry. J Am Med Inform Assoc. 2006, 13 (2): 138-147. 10.1197/jamia.M1809.

    Article  PubMed  PubMed Central  Google Scholar 

  16. Osheroff JA: Improving Medication Use and Outcomes with Clinical Decision Support: A Step-by-Step Guide. 2009, Chicago, IL: Health Information and Management Systems Society

    Google Scholar 

  17. Riedmann D, Jung M, Hackl WO, Stühlinger W, van der Sijs H, Ammenwerth E: Development of a context model to prioritize drug safety alerts in CPOE systems. BMC Med Inform Decis Mak. 2011, 11: 35-10.1186/1472-6947-11-35.

    Article  PubMed  PubMed Central  Google Scholar 

  18. Seidling HM, Schmitt SP, Bruckner T, Kaltschmidt J, Pruszydlo MG, Senger C, Bertsche T, Walter-Sack I, Haefeli WE: Patient-specific electronic decision support reduces prescription of excessive doses. Qual Saf Health Care. 2010, 19 (5): e15-10.1136/qshc.2009.033175.

    CAS  PubMed  Google Scholar 

  19. Weingart SN, Toth M, Sands DZ, Aronson MD, Davis RB, Phillips RS: Physicians' decisions to override computerized drug alerts in primary care. Arch Intern Med. 2003, 163 (21): 2625-2631. 10.1001/archinte.163.21.2625.

    Article  PubMed  Google Scholar 

  20. Ash JS, Sittig DF, Dykstra R, Campbell E, Guappone K: The unintended consequences of computerized provider order entry: findings from a mixed methods exploration. Int J Med Inform. 2009, 78 (Suppl 1): S69-S76.

    Article  PubMed  Google Scholar 

  21. Ash JS, Sittig DF, Poon EG, Guappone K, Campbell E, Dykstra RH: The extent and importance of unintended consequences related to computerized provider order entry. J Am Med Inform Assoc. 2007, 14 (4): 415-423. 10.1197/jamia.M2373.

    Article  PubMed  PubMed Central  Google Scholar 

  22. Isaac T, Weissman JS, Davis RB, Massagli M, Cyrulik A, Sands DZ, Weingart SN: Overrides of medication alerts in ambulatory care. Arch Intern Med. 2009, 169 (3): 305-311. 10.1001/archinternmed.2008.551.

    Article  PubMed  Google Scholar 

  23. van der Sijs H: Drug Safety Alerting in Computerized Physician Order Entry - Unraveling and Counteracting Alert Fatigue. 2009, Rotterdam: Erasmus University

    Google Scholar 

  24. Getty DJ, Swets JA, Pickett RM, Gonthier D: System operator response to warnings of danger: a laboratory investigation of the effects of the predictive value of a warning on human response time. J Exp Psychol Appl. 1995, 1 (1): 19-33.

    Article  Google Scholar 

  25. Del Beccaro M, Villanueva R, Knudson K, Harvey E, Langle J, Paul W: Decision Support Alerts for Medication Ordering in a Computerized Provider Order Entry (CPOE) System: a systematic approach to decrease alerts. Appl Clin Inform. 2010, 1: 346-362. 10.4338/ACI-2009-11-RA-0014.

    Article  Google Scholar 

  26. Resetar E, Reichley RM, Noirot LA, Doherty JA, Dunagan WC, Bailey TC: Strategies for reducing nuisance alerts in a dose checking application. AMIA Annu Symp Proc. 2005, 624-628.

    Google Scholar 

  27. Resetar E, Reichley RM, Noirot LA, Dunagan WC, Bailey TC: Implementing daily dosing rules using a commercial rule base. AMIA Annu Symp Proc. 2006, 1073-

    Google Scholar 

  28. Reichley RM, Seaton TL, Resetar E, Micek ST, Scott KL, Fraser VJ, Dunagan WC, Bailey TC: Implementing a commercial rule base as a medication order safety net. J Am Med Inform Assoc. 2005, 12 (4): 383-389. 10.1197/jamia.M1783.

    Article  PubMed  PubMed Central  Google Scholar 

  29. Paterno MD, Maviglia SM, Gorman PN, Seger DL, Yoshida E, Seger AC, Bates DW, Gandhi TK: Tiering drug-drug interaction alerts by severity increases compliance rates. J Am Med Inform Assoc. 2009, 16 (1): 40-46. 10.1197/jamia.M2808.

    Article  PubMed  PubMed Central  Google Scholar 

  30. Anton C, Nightingale PG, Adu D, Lipkin G, Ferner RE: Improving prescribing using a rule based prescribing system. Qual Saf Health Care. 2004, 13 (3): 186-190. 10.1136/qshc.2003.006882.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  31. van der Sijs H, Lammers L, van den Tweel A, Aarts J, Berg M, Vulto A, van Gelder T: Time-dependent drug-drug interaction alerts in care provider order entry: software may inhibit medication error reductions. J Am Med Inform Assoc. 2009, 16 (6): 864-868. 10.1197/jamia.M2810.

    Article  PubMed  PubMed Central  Google Scholar 

  32. van der Sijs H, Aarts J, van Gelder T, Berg M, Vulto A: Turning off frequently overridden drug alerts: limited opportunities for doing it safely. J Am Med Inform Assoc. 2008, 15 (4): 439-448. 10.1197/jamia.M2311.

    Article  PubMed  PubMed Central  Google Scholar 

  33. McCoy AB, Waitman LR, Lewis JB, Wright JA, Choma DP, Miller RA, Peterson JF: A framework for evaluating the appropriateness of clinical decision support alerts and responses. J Am Med Inform Assoc. 2012, 19 (3): 346-352. 10.1136/amiajnl-2011-000185.

    Article  PubMed  Google Scholar 

  34. Perna G: Clinical alerts that cried wolf. As clinical alerts pose physician workflow problems, healthcare IT leaders look for answers. Healthc Inform. 2012, 29 (4): 18, 20-

    PubMed  Google Scholar 

  35. Kesselheim AS, Cresswell K, Phansalkar S, Bates DW, Sheikh A: Clinical decision support systems could be modified to reduce 'alert fatigue' while still minimizing the risk of litigation. Health Aff (Millwood). 2011, 30 (12): 2310-2317. 10.1377/hlthaff.2010.1111.

    Article  Google Scholar 

  36. Hoffman S, Podgurski A: Drug-drug interaction alerts: emphasizing the evidence. St Louis Univ J Health Law Pol. 2012, 5: 297-310.

    Google Scholar 

  37. Ridgely MS, Greenberg MD: Too many alerts, too much liability: sorting through the malpractice implications of drug-drug interaction clinical decision support. St Louis Univ J Health Law Pol. 2012, 5: 257-296.

    Google Scholar 

  38. Weingart SN, Simchowitz B, Padolsky H, Isaac T, Seger AC, Massagli M, Davis RB, Weissman JS: An empirical model to estimate the potential impact of medication safety alerts on patient safety, health care utilization, and cost in ambulatory care. Arch Intern Med. 2009, 169 (16): 1465-1473. 10.1001/archinternmed.2009.252.

    Article  PubMed  Google Scholar 

  39. Troiano D, Jones MA, Smith AH, Chan RC, Laegeler AP, Le T, Flynn A, Chaffee BW: The need for collaborative engagement in creating clinical decision-support alerts. Am J Health Syst Pharm. 2013, 70 (2): 150-153. 10.2146/ajhp120435.

    Article  PubMed  Google Scholar 

  40. Coleman JJ, Nwulu U, Ferner RE: Decision support for sensible dosing in electronic prescribing systems. J Clin Pharm Ther. 2011, 37 (4): 415-419.

    Article  PubMed  Google Scholar 

  41. Ferner RE, Coleman JJ: An algorithm for integrating contraindications into electronic prescribing decision support. Drug Saf. 2010, 33 (12): 1089-1096. 10.2165/11539390-000000000-00000.

    Article  PubMed  Google Scholar 

  42. Seidling HM, Storch CH, Bertsche T, Senger C, Kaltschmidt J, Walter-Sack I, Haefeli WE: Successful strategy to improve the specificity of electronic statin-drug interaction alerts. Eur J Clin Pharmacol. 2009, 65 (11): 1149-1157. 10.1007/s00228-009-0704-x.

    Article  CAS  PubMed  Google Scholar 

  43. Kawamoto K, Hongsermeier T, Wright A, Lewis J, Bell DS, Middleton B: Key principles for a national clinical decision support knowledge sharing framework: synthesis of insights from leading subject matter experts. J Am Med Inform Assoc. 2013, 20 (1): 199-207. 10.1136/amiajnl-2012-000887.

    Article  PubMed  PubMed Central  Google Scholar 

  44. Aarts J, Koppel R: Implementation of computerized physician order entry in seven countries. Health Aff (Millwood). 2009, 28 (2): 404-414. 10.1377/hlthaff.28.2.404.

    Article  Google Scholar 

  45. van der Sijs H, Bouamar R, van Gelder T, Aarts J, Berg M, Vulto A: Functionality test for drug safety alerting in computerized physician order entry systems. Int J Med Inform. 2010, 79 (4): 243-251. 10.1016/j.ijmedinf.2010.01.005.

    Article  PubMed  Google Scholar 

  46. van Doormaal JE, Rommers MK, Kosterink JGW, Teepe-Twiss IM, Haaijer-Ruskamp FM, Mol PGM: Comparison of methods for identifying patients at risk of medication-related harm. Qual Saf Health Care. 2010, 19: 1-5. 10.1097/QMH.0b013e3181d1391c.

    Article  Google Scholar 

  47. Wickens CD, Dixon SR: The benefits of imperfect diagnostic automation: a synthesis of the literature. Theor Issues Ergon. 2007, 8 (3): 201-212. 10.1080/14639220500370105.

    Article  Google Scholar 

  48. Russ AL, Zillich AJ, McManus MS, Doebbeling BN, Saleem JJ: A human factors investigation of medication alerts: barriers to prescriber decision-making and clinical workflow. AMIA Annu Symp Proc. 2009, 2009: 548-552.

    PubMed  PubMed Central  Google Scholar 

  49. Phansalkar S, Edworthy J, Hellier E, Seger DL, Schedlbauer A, Avery AJ, Bates DW: A review of human factors principles for the design and implementation of medication safety alerts in clinical information systems. J Am Med Inform Assoc. 2010, 17 (5): 493-501. 10.1136/jamia.2010.005264.

    Article  PubMed  PubMed Central  Google Scholar 

  50. Zachariah M, Phansalkar S, Seidling HM, Neri PM, Cresswell KM, Duke J, Bloomrosen M, Volk LA, Bates DW: Development and preliminary evidence for the validity of an instrument assessing implementation of human-factors principles in medication-related decision-support systems–I-MeDeSA. J Am Med Inform Assoc. 2011, 18 (Suppl 1): i62-i72. 10.1136/amiajnl-2011-000362.

    Article  PubMed  PubMed Central  Google Scholar 

  51. Reason J: Human Error. 1990, Cambridge, UK: Cambridge University Press

    Book  Google Scholar 

  52. Driving Quality and Performance Measurement—A Foundation for Clinical Decision Support. A Consensus Report. [http://www.qualityforum.org/Publications/2010/12/Driving_Quality_and_Performance_Measurement_-_A_Foundation_for_Clinical_Decision_Support.aspx]

  53. Ferner RE, Aronson JK: Clarification of terminology in medication errors: definitions and classification. Drug Saf. 2006, 29 (11): 1011-1022. 10.2165/00002018-200629110-00001.

    Article  PubMed  Google Scholar 

  54. Lisby M, Nielsen LP, Brock B, Mainz J: How are medication errors defined? A systematic literature review of definitions and characteristics. Int J Qual Health Care. 2010, 22 (6): 507-518. 10.1093/intqhc/mzq059.

    Article  CAS  PubMed  Google Scholar 

  55. Weingart SN, Seger AC, Feola N, Heffernan J, Schiff G, Isaac T: Electronic drug interaction alerts in ambulatory care: the value and acceptance of high-value alerts in US medical practices as assessed by an expert clinical panel. Drug Saf. 2011, 34 (7): 587-593. 10.2165/11589360-000000000-00000.

    Article  PubMed  Google Scholar 

  56. Phansalkar S, Desai AA, Bell D, Yoshida E, Doole J, Czochanski M, Middleton B, Bates DW: High-priority drug-drug interactions for use in electronic health records. J Am Med Inform Assoc. 2012, 19 (5): 735-743. 10.1136/amiajnl-2011-000612.

    Article  PubMed  PubMed Central  Google Scholar 

  57. Phansalkar S, van der Sijs H, Tucker AD, Desai AA, Bell DS, Teich JM, Middleton B, Bates DW: Drug-drug interactions that should be non-interruptive in order to reduce alert fatigue in electronic health records. J Am Med Inform Assoc. 2013, 20 (3): 489-493. 10.1136/amiajnl-2012-001089.

    Article  PubMed  Google Scholar 

  58. Dean B, Schachter M, Vincent C, Barber N: Causes of prescribing errors in hospital inpatients: a prospective study. Lancet. 2002, 359 (9315): 1373-1378. 10.1016/S0140-6736(02)08350-2.

    Article  PubMed  Google Scholar 

  59. Andersson ML, Bottiger Y, Lindh JD, Wettermark B, Eiermann B: Impact of the drug-drug interaction database SFINX on prevalence of potentially serious drug-drug interactions in primary health care. Eur J Clin Pharmacol. 2013, 69 (3): 565-571. 10.1007/s00228-012-1338-y.

    Article  CAS  PubMed  Google Scholar 

  60. Metzger J, Welebob E, Bates DW, Lipsitz S, Classen DC: Mixed results in the safety performance of computerized physician order entry. Health Aff (Millwood). 2010, 29 (4): 655-663. 10.1377/hlthaff.2010.0160.

    Article  Google Scholar 

  61. Scott GP, Shah P, Wyatt JC, Makubate B, Cross FW: Making electronic prescribing alerts more effective: scenario-based experimental study in junior doctors. J Am Med Inform Assoc. 2011, 18 (6): 789-798. 10.1136/amiajnl-2011-000199.

    Article  PubMed  PubMed Central  Google Scholar 

  62. Chuang JH, Hripcsak G, Heitjan DF: Design and analysis of controlled trials in naturally clustered environments: implications for medical informatics. J Am Med Inform Assoc. 2002, 9 (3): 230-238. 10.1197/jamia.M0997.

    Article  PubMed  PubMed Central  Google Scholar 

Pre-publication history

Download references

Acknowledgments

We thank Dr Paddie Murphy for her assistance in documenting the discussions of the workshop.

Funding

Accommodation, travel, and workshop fees for the authors were provided by the European Regional Development Fund (ERDF). The ERDF had no role in the writing of the manuscript or in the decision to submit the manuscript for publication

JJC, REF and SMcD received funding from the National Institute for Health Research (NIHR) through the Collaborations for Leadership in Applied Health Research and Care for Birmingham and Black Country (CLAHRC-BBC) programme. JJC and AS have received funding from the NIHR programme grant to investigate the implementation, adoption and effectiveness of ePrescribing systems in English hospitals. The views expressed are those of the authors and not necessarily those of the NHS, the NIHR or the Department of Health.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jamie J Coleman.

Additional information

Competing interests

All authors have no conflict of interest to declare.

Authors’ contributions

All authors have (1) contributed to the concept of the paper; (2) drafted the paper or revised it critically for important intellectual content; and (3) have given their final approval of the submitted paper.

An erratum to this article is available at http://dx.doi.org/10.1186/1472-6947-13-122.

Electronic supplementary material

Rights and permissions

This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Coleman, J.J., van der Sijs, H., Haefeli, W.E. et al. On the alert: future priorities for alerts in clinical decision support for computerized physician order entry identified from a European workshop. BMC Med Inform Decis Mak 13, 111 (2013). https://doi.org/10.1186/1472-6947-13-111

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/1472-6947-13-111

Keywords