Utilizing Nasal-Tragus Length to Estimate Optimal Endotracheal Tube Depth for Neonates in Taiwan

  • Original Article
  • Published:
The Indian Journal of Pediatrics Aims and scope Submit manuscript

Abstract

Objective

To assess the application of the nasal-tragus length (NTL) to predict the proper endotracheal tube (ETT) depth; also, as relatively thinner size of Asian than Caucasian, the fitness of using the NTL to estimate the optimal ETT depth for neonates in Taiwan was examined.

Methods

The newborn infants who do need intubation orally were included. Those with midface dysmorphism, craniofacial anomalies, head trauma and/or facial injury in whom it was unable to measure NTL, were excluded. The data were collected after a satisfactory ETT tip position was confirmed on chest roentgenogram. Equations were established via the polynomial and the linear regression of the NTL and the actual ETT; simplified formulae as NTL+0.5 and NTL+1 were assumed accordingly. Paired t test was used to assess the coefficients.

Results

The 63 neonates, weighing 410 through 4,196 g and with gestation 21 through 41 weeks, were enrolled. No statistical difference was found between the actual ETT depth and the estimated ETT depth via the NTL+1 cm in neonates weighing ≤2,500 g (n = 41, p = 0.06), and also between the actual ETT depth and the estimated ETT depth via the NTL+0.5 cm in group weighing >2,500 g (n = 22, p = 0.171).

Conclusions

Using the NTL to predict the optimal ETT depth with the formula, NTL plus 1 cm, was clinically practical for newborn infants in Taiwan weighing ≤2,500 g, and a modified formula, NTL plus 0.5 cm, was more suitable for neonates weighing >2,500 g.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Kattwinkel J. Textbook of neonatal resuscitation. Lesson 5, Endotracheal intubation. 5th ed. Dallas; American Heart Association and Elk Grove Village, IL: American Academy of Pediatrics; 2006. p. 42.

  2. Gomella TL. Endotracheal intubation. In: Gomella TL, Cunningham MD, Eyal FG, Zenk KE, editors. Neonatology: management, procedures, on-call problems, diseases, and drugs. 5th ed. United States of America: McGraw-Hill; 2004. p. 172–4.

  3. Blayney MP, Logan DR. First thoracic vertebral body as reference for endotracheal tube placement. Arch Dis Child Fetal Neonatal Ed. 1994;71:F32–5.

    Article  PubMed  CAS  Google Scholar 

  4. Mainie P, Carmichael A, McCullough S, Kempley ST. Endotracheal tube position in neonates requiring emergency interhospital transfer. Am J Perinatol. 2006;23:121–4.

    Article  PubMed  CAS  Google Scholar 

  5. Kuhns LR, Poznanski AK. Endotracheal tube position in the infant. J Pediatr. 1971;78:991–6.

    Article  PubMed  CAS  Google Scholar 

  6. Joshi VV, Mandavia SG, Stern L, Wiglesworth F. Acute lesions induced by endotracheal intubation. Occurrence in the upper respiratory tract of newborn infants with respiratory distress syndrome. Am J Dis Child. 1972;124:646–9.

    PubMed  CAS  Google Scholar 

  7. McMillan DD, Rademaker AW, Buchan KA, Reid A, Machin G, Sauve RS. Benefits of orotracheal and nasotracheal intubation in neonates requiring ventilatory assistance. Pediatrics. 1986;77:39–44.

    PubMed  CAS  Google Scholar 

  8. Donn SM, Kuhns LR. Mechanism of endotracheal tube movement with change of head position in the neonate. Pediatr Radiol. 1980;9:37–40.

    Article  PubMed  CAS  Google Scholar 

  9. Rost JR, Frush DP, Auten RL. Effect of neck position on endotracheal tube location in low birth weight infants. Pediatr Pulmonol. 1999;27:199–202.

    Article  PubMed  CAS  Google Scholar 

  10. Sugiyama K, Yokoyama K. Reliability of auscultation of bilateral breath sounds in confirming endotracheal tube position. Anesthesiology. 1995;83:1373.

    Article  PubMed  CAS  Google Scholar 

  11. Shukla HK, Hendricks-Munoz KD, Atakent Y, Rapaport S. Rapid estimation of insertional length of endotracheal intubation in newborn infants. J Pediatr. 1997;131:561–4.

    Article  PubMed  CAS  Google Scholar 

  12. Whyte KL, Levin R, Powls A. Clinical audit: optimal positioning of endotracheal tubes in neonates. Scott Med J. 2007;52:25–7.

    PubMed  CAS  Google Scholar 

  13. Tochen ML. Orotracheal intubation in the newborn infant: a method for determining depth of tube insertion. J Pediatr. 1979;95:1050–1.

    Article  PubMed  CAS  Google Scholar 

  14. Peterson J, Johnson N, Deakins K, Wilson-Costello D, Jelovsek JE, Chatburn R. Accuracy of the 7-8-9 rule for endotracheal tube placement in the neonate. J Perinatol. 2006;26:333–6.

    Article  PubMed  CAS  Google Scholar 

  15. Embleton ND, Deshpande SA, Scott D, Wright C, Milligan DW. Foot length, an accurate predictor of nasotracheal tube length in neonates. Arch Dis Child Fetal Neonatal Ed. 2001;85:F60–4.

    Article  PubMed  CAS  Google Scholar 

  16. Loew A, Thibeault DW. A new and safe method to control the depth of endotracheal intubation in neonates. Pediatrics. 1974;54:506–8.

    PubMed  CAS  Google Scholar 

  17. Weiss M, Balmer C, Dullenkopf A, et al. Intubation depth markings allow an improved positioning of endotracheal tubes in children. Can J Anaesth. 2005;52:721–6.

    Article  PubMed  Google Scholar 

  18. Molendijk H. Use of the black area on the tubetip for rapid estimation of insertional depth of endotracheal tubes in neonates: a potential hazard [Letter]. Arch Dis Child Fetal Neonatal Ed. 2001;85:77.

    Article  Google Scholar 

  19. Galicinao J, Bush AJ, Godambe SA. Use of bedside ultrasonography for endotracheal placement in pediatric patients: a feasibility study. Pediatrics. 2007;120:1297–303.

    Article  PubMed  Google Scholar 

  20. Sundaram V, Kumar A, Kumar P. Bedside ultrasonography and endotracheal placement: a long way to go [Letter]. Pediatrics. 2008;122:213–4.

    Article  PubMed  Google Scholar 

  21. Verghese ST, Hannallah RS, Slack MC, Cross RR, Patel KM. Auscultation of bilateral breath sounds does not rule out endobronchial intubation in children. Anesth Analg. 2004;99:56–8.

    Article  PubMed  Google Scholar 

  22. Weiss M, Knirsch W, Kretschmar O, et al. Tracheal tube-tip displacement in children during head-neck movement—a radiological assessment. Br J Anaesth. 2006;96:486–91.

    Article  PubMed  CAS  Google Scholar 

Download references

Conflict of interest

All authors have no relevant financial interests related to the material in the manuscript to disclose.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Tzu-Chiang Wang.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Wang, TC., Kuo, LL. & Lee, CY. Utilizing Nasal-Tragus Length to Estimate Optimal Endotracheal Tube Depth for Neonates in Taiwan. Indian J Pediatr 78, 296–300 (2011). https://doi.org/10.1007/s12098-010-0278-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12098-010-0278-8

Keywords

Navigation