Table 1

Ventilator mode and initial settings

AgeModeFTiPiPsFiO2PEEPVsens
4 weeks < age ≤ 1 yearSIMV-PC300.67121050%51
1 year < age ≤ 3 yearsSIMV-PC250.80121050%51
3 years < age ≤ 12 yearsSIMV-PC200.86121050%51
Age >12 yearsSIMV-PC151.0121050%51
  • F, frequency; FiO2, fraction of inspired oxygen ; PEEP, positive end-expiratory pressure ; Pi, inspiratory pressure above PEEP; Ps, pressure of support; SIMV-PC, synchronised intermittent mandatory ventilation-pressure control ; Ti, inspiratory time .