Table 2

Quality indicators of included instruments

Visual acuityVisual fieldOcular alignmentOcular movementQuality of lifeFunctional vision
LogMARPeripheral perimetryPrism cover testRotation gradingVFQ-25Radner reading
Use in target populationYesYesYesYesYesYes
Content validity
Reliability++++++
Responsiveness++++++
Internal consistency++++++
Structural validity++++++
Measurement error++++++
Hypothesis testing++++++
Criterion validity++++++
Cross-cultural validity++++++
Quality of evidenceHighHighModerateModerateModerateModerate
Feasibility
Patient comprehensionWidely understoodWidely understoodWidely understoodWidely understoodWidely understoodWidely understood
InterpretabilityClear usageClear usageClear usageClear usageClear usageClear usage
Ease of administrationHighRelativeHighHighHighHigh
Length of instrumentSmall—small number of linesModerate—can take time per eyeSmallSmallModerateModerate
Completion timeWithin minutes15–20 minWithin minutesWithin minutesRelativeRelative
Patient mental ability levelLow—use with childrenMediumLowLowMediumMedium
Ease of standardisationHigh easeHighHighHighModerateModerate
Clinician comprehensionWidely understoodWidely understoodWidely understoodWidely understoodWidely understoodWidely understood
Type of instrumentLetter chartPerimeterOccluder, target, prismsOccluder, targetQuestionnaireReading paragraphs
CostLowHighLowLowRelative to licenceLow
Required equipmentLetter chartPerimeterOccluder, target, prismsOccluder, targetQuestionnaireBook
Type of administrationClinician-ledClinician ledClinician ledClinician ledClinician-led
Self-administered
Clinician led
Availability in different settingsYesYesYesYesYesYes
CopyrightPer companyPer companyPer companyPer companyPer companyPer company
Patient physical ability levelMinimalRelativeMinimalMinimalRelativeRelative
Regulatory approvalNoNoNoNoNoNo
Ease of score calculationHigh easeHigh easeHigh easeHigh easeHigh easeHigh ease
  • LogMAR, Logarithm of the Minimal Angle of Resolution; VFQ-25, Visual Function Questionnaire 25.