Table 4

Number, frequency and relationship of discrepancies to resultant errors with subanalysis of major discrepancies that resulted in large magnitude and clinically significant errors

Stage of deviationTotal discrepancies (n)Relationship to resultant errors
No contribution n (%*)Minor contribution n (%*)Discrepancies which made a major contribution to a medication error
Major contribution, total (n, %*)Discrepancies that resulted in clinically significant errors (n, %*) †Discrepancies that resulted in large magnitude errors n (%*) ‡
Overall884710 (80)104 (12)70 (8)33 (47)31 (44)
Ordering phase170159 (94)2 (1)9 (5)5 (23)6 (22)
 Determine dose2921 (72)1 (3)7 (24)5 (23)6 (22)
 Dose from memory42 (50)2 (50)1 (4)
 Dose from formulary106 (60)1 (10)3 (30)3 (14)3 (11)
 Dose from other resource1110 (91)1 (9)1 (5)1 (4)
 Dose calculation43 (75)1 (25)1 (5)1 (4)
 Issue order141138 (98)1 (1)2 (1)
 Issue verbal order136134 (98)1 (1)1 (1)
 Issue written order54 (80)1 (20)
Preparation phase588456 (78)89 (15)43 (7)17 (77)13 (48)
 Check order196 (32)9 (47)4 (21)3 (14)1 (4)
 Check drug name11 (100)1 (5)1 (4)
 Check dose for indication155 (33)8 (53)2 (13)1 (5)
 Check calculation11 (100)
 Check route and timing21 (50)1 (50)1 (5)
 Preparation, actual310263 (85)8 (3)39 (13)14 (64)12 (44)
 Find correct medication and strength of vial22 (100)
 Check intravenous administration guidance4222 (52)1 (2)19 (45)9 (41)6 (22)
 Check ampoule11 (100)
 Check reconstitution fluid and volume73 (43)1 (14)3 (43)
 Convert milligrams to millilitres72 (29)5 (71)3 (14)4 (15)
 Find correct syringe and draw neat volume83 (38)5 (63)1 (5)1 (4)
 Determine correct concentration for route22 (100)
 Calculate further diluent volume and dilute124 (33)1 (8)7 (58)1 (5)1 (4)
 Label syringe with drug name, dose and concentration if appropriate231227 (98)4 (2)
 Double checking259187 (72)72 (27)
 Check reconstitution95 (57)4 (44)
 Check dose and neat volume6948 (70)21 (30)
 Check diluent volume and total volume separately8663 (73)23 (27)
 Check ampoule+expiry2926 (90)3 (10)
 Check rate/method6645 (68)21 (32)
Administration phase288 (29)2 (7)18 (64)11 (50)12 (44)
 Boluses: inject21 (50)1 (50)
 Infusions: determine run rate81 (13)7 (88)5 (23)5 (19)
 Determine Y-site compatibility22 (100)
 Determine delivery rate for continuous infusions73 (43)4 (57)3 (14)4 (15)
 Programme infusion pump92 (22)7 (78)3 (14)3 (11)
Recording8888 (100)
  • *The denominator for percentages is the total number of discrepancies in each row.

  • †Number and percentage of clinically significant errors (severity score >3) with major contributory discrepancies made at each specific step, of a total of 22 clinically significant errors.

  • ‡Number and percentage of large magnitude errors (deviation from recommended dosing range (DRDR) or deviation from recommended dosing rate (DRDRate) >25%) with major contributory discrepancies made at each specific step, of a total of 27 large magnitude errors.