Article Text

Download PDFPDF

Focused ultrasound examination of the chest on patients admitted with acute signs of respiratory problems: a study protocol for a pragmatic randomised controlled multicentre trial
  1. M Riishede1,2,3,
  2. C B Laursen2,4,
  3. L S Teglbjærg3,
  4. A T Lassen2,5,
  5. G Baatrup1,2
  1. 1Department of Surgery (A), Odense University Hospital, Svendborg, Denmark
  2. 2Institute of Clinical Research, University of Southern Denmark, SDU-Odense, Denmark
  3. 3Department of Internal Medicine & Emergency Medicine (M/FAM), Odense University Hospital, Svendborg, Denmark
  4. 4Department of Respiratory Medicine, Odense University Hospital, Odense, Denmark
  5. 5Department of Emergency Medicine, Odense University Hospital, Odense, Denmark
  1. Correspondence to Minna Riishede; Minna.Riishede{at}rsyd.dk

Abstract

Introduction Patients with acute respiratory problems poses a diagnostic challenge because similar symptoms can be caused by various pathological conditions. Focused ultrasound examination (f-US) of the heart and lungs has proven to increase the diagnostic accuracy in these patients. In this protocol of a randomised multicentre trial, we study the effect of f-US of the heart and lungs in patients with respiratory problems performed by emergency physicians (EP) as soon as the patient arrives to the emergency department (ED). The primary outcome is the number of patients with a correct presumptive diagnosis at 4 hours from admission.

Methods and analysis This is a semiblinded randomised prospective study. 288 patients will be included and randomised into the control or intervention group. All patients receive a standard diagnostic evaluation by the EP to assess the primary presumptive diagnosis. Investigators are EP, with varying degrees of experience in f-US, who perform an f-US of the heart and lungs in patients in both treatment arms. f-US results in the intervention group are non-blinded to the treating EP to be included in the assessment of the 4-hour presumptive diagnosis. As standard for correct diagnosis, we perform a blinded journal audit after discharge. As primary analysis, we use the intention-to-treat analysis.

Conclusions This study is the first multicentre trial in EDs to investigate whether f-US, in the hands of the EP, increases the proportion of correct diagnosis at 4 hours after arrival when performed on patients with respiratory problems.

Ethics and dissemination This trial is conducted in accordance with the Helsinki II Declaration and approved by the Danish Data Protection Agency and the Committee on Biomedical Research Ethics for the Region of Southern Denmark. Results will be published in accordance with the CONSORT statement in a peer-reviewed scientific journal regardless of the outcome.

Trial registration number NCT02550184; Pre-results.

  • RESPIRATORY MEDICINE (see Thoracic Medicine)
  • ACCIDENT & EMERGENCY MEDICINE

This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Introduction

Patients arriving to the emergency department (ED) with symptoms of acute respiratory problems are often a diagnostic challenge. Despite similar clinical symptoms, the aetiology can vary and require different treatments and interventions.1 Earlier studies have found that at least one diagnosis was missed in >20% of these patients and that >30% of them received a suboptimal treatment leading to increased length of stay at hospital and increased mortality.1–3 The assessment of a fast and correct diagnosis is therefore of high importance in these patients where instant treatment may be lifesaving.1 ,2 ,4–6

Focused ultrasound examination (f-US) of the lungs and heart has, over the past years, emerged as a fast, non-invasive, bedside tool for diagnosing diseases in the chest. This has led to the development of evidence-based guidelines describing indications, technical performance and interpretation of ultrasound of the lungs and heart,7–9 as well as guidelines for the implementation of f-US on patients in the EDs and intensive care units.10–13

Alongside standard paraclinical (eg, blood samples, ECG, chest X-ray) and physical examination, several trials have investigated the impact of an f-US on the diagnostic accuracy of some of the most common diseases encountered in patients with symptoms of respiratory problems in the EDs (eg, pneumonia, chronic obstructive lung disease, pulmonary oedema, lung embolism, acute heart failure).2 ,3 ,14–29 Most of these studies proved a high diagnostic accuracy when using an f-US alongside standard diagnostic testing compared to standard diagnostic testing alone. Some even found that the diagnostic accuracy of certain pulmonary diseases was superior when it was assessed using f-US compared to a chest X-ray examination.18 One single centre study found a significant increase in diagnostic accuracy as well as in correctly prescribed treatment at 4 hours after the patient’s arrival to the ED. This was made by adding an f-US of the heart, lungs and deep veins to standard clinical testing of patients with respiratory problems.3

Unfortunately, the results from these studies are not directly transferable to daily clinical practice as most of them are designed as single centre studies and some even performed by single investigators highly skilled in f-US.2 ,3 ,14 ,16 ,18–20 ,22

In this study, we aim to investigate whether adding an f-US of the lungs and heart to the standard diagnostic examination in patients with signs and symptoms of respiratory problems increases the proportion of patients with a correct diagnosis established at 4 hours after admittance. The study will be performed as a randomised pragmatic multicentre trial. The f-US will be performed by emergency physicians (EP) who attend to patients in the ED on a regular basis.

Methods

Design

The trial is designed as a prospective randomised semiblinded, multicentre study with a parallel group design, an allocation ratio of 1:1 and as a superiority study. The protocol has been developed from the single centre study performed by one expert-investigator.3 As far as possible, we mimic the study design and transfer it into a multicentre design as well as comply with the few points of criticism the study has received.30

Study flow and patient enrolment

Patient enrolment started in October 2015 and is estimated to be finished in December 2016. We aim to include 288 patients admitted to nine different EDs. Enrolment will be performed in a non-consecutive manner by local investigators from each ED (figure 1). Patients comprise of those who are acutely admitted to the ED with symptoms of respiratory problems as their primary symptom. The investigator will screen the patients for inclusion according to the inclusion and exclusion criteria shortly after their arrival (box 1).

Box 1

Inclusion and exclusion criteria for enrolment

Inclusion criteria.

All four criteria have to be fulfilled.

  • 1. The patient is 18 years or more.

  • 2. The patient has arrived acutely to the emergency department (ED).

  • 3. The patient presents with one or more of the following signs and symptoms as the primary symptom:

  • Cough.

  • Dyspnoea.

  • Chest pain.

  • Respiration frequency >20/min.

  • Peripheral oxygen saturation <95%.

  • 4. Written informed consent from habile patient.

Exclusion criteria.

  • 1. The patient is not capable of giving informed consent.

  • 2. The focused ultrasound examination (f-US) of the lungs or the heart has already been performed by others than the investigator in relation to the primary assessment.

  • 3. The randomisation and f-US cannot be performed within 4 hours from the patient′s admittance to the ED.

Figure 1

Enrolment and patient flow in the study.

Given that all inclusion criteria and none of the exclusion criteria are fulfilled, the investigator will provide the patient with oral and written information (see online supplementary appendix I) about the study in order to achieve informed consent whereafter he can draw a randomisation number in the assigned database.

A primary presumptive diagnosis upon the patient’s arrival will be assessed by the EP for patients in both groups using the standard method of diagnostic assessment (eg, clinical assessment, blood samples, ECG, chest X-ray). Without knowledge of the primary presumptive diagnosis, the investigator performs an f-US of the heart and lungs on patients in the intervention and control group and gathers information on the basic clinical values upon the patient’s arrival.

The f-US results from patients in the control group remain blinded for the treating physician. But for patients in the intervention group, the f-US results will be non-blinded to the treating physician once he has declared his primary presumptive diagnosis to the investigator. Non-blinding of f-US results will be performed by the investigator in oral and in writing, on a paper record, marked with the patient’s personal ID number and stored in an accessible briefcase in the ED. Once the f-US results are non-blinded to the EP, he can re-evaluate his primary presumptive diagnosis and treatment.

Further diagnostic evaluation and treatment will proceed in accordance with the ED’s clinical guidelines.

To ensure that we reach target sample size by an adequate patient enrolment, we have taken the following precautions: a pilot study was performed in the ED in one of the smallest hospitals participating in this trial and showed that an average of four eligible patients per day on an 8-hour shift in daytime. The investigators work between 1 and 4 days per week in the ED and they agreed on an inclusion rate of 20–25 patients per investigator. This gives an estimate of 12–15 investigators necessary to include 288 patients and an estimate of inclusion time of 1–4 weeks. To this we added the risk of investigators pausing inclusion due to busy shifts, holiday, sick leave or maternity leave or even dropping out of the project prior to completing their inclusion rates.

We here ended with a need for 20 investigators and an inclusion time of 15 months, including 3 months, for a local initiation of inclusion in the participating centres.

Recruitment of investigators

Investigators are found via MR’s network of ultrasound enthusiasts and by oral presentations of the study on conferences and meetings among physicians and researchers of emergency medicine in Denmark. Once a potential investigator proved interest in participating in the study, MR supplied him or her with documents about the expected tasks as investigator, a description of the protocol, agreements on affiliation on the final product and a questionnaire regarding: their level of education, their attachment to the ED, their ultrasound skills, a description of the type of ultrasound equipment in the ED and the availability of this.

If the investigator fulfilled the basic requirements and still wished to become an investigator, MR contacted the management of the ED, by email, to ask for permission to initiate the trial in their department. Attached to this request was the study protocol along with the expected tasks of the investigator and the agreements on affiliation of the final product. Once the authorisation from the department leaders was attained, we agreed on a date for the educational programme, regarding the database and the ultrasound protocol. This programme was set to take place in the investigators’ own environment. Until then, the investigators were provided with regular updates on study progress and with e-learn material about the ultrasound protocol.

Standards and diagnoses

As standard for the final diagnoses, we will make a blinded journal audit using the results from the f-US as well as predefined diagnostic criteria (see online supplementary appendix II). The audit will be undertaken once the patient has left the hospital. It will be performed by two physicians who, in case of discrepancy, will be complemented by a third auditor who will set the final decision.

As standard for a correct interpretation of the f-US, specialists in ultrasound of the lungs and the heart will perform a blinded audit using predefined diagnostic criteria (see online supplementary appendix III). The specialists will be blinded with respect to the investigator’s evaluation of the f-US. All f-US recordings are saved as raw data.

The primary presumptive diagnosis is assessed by the EP who writes it on a predesigned paper record and hands it to the investigator prior to non-blinding of the f-US results. Subsequently, the investigator adds the primary presumptive diagnosis to the database.

The 4-hour presumptive diagnosis will be found by a blinded medical journal audit once the patient has left the hospital. For this, we use the last performed evaluation registered in the patient’s medical record within 4 hours from admission to the ED. The specific cut-off at 4 hours is chosen because several EDs throughout Denmark have a 4-hour time limit when primary results (eg, blood sample, ECG, X-ray) and a presumptive diagnosis with relevant treatment should be started.

Study sites

The study sites comprise nine Danish EDs, hereof three EDs of tertiary referral hospitals. All participating EDs have admissions to the medical unit and represent a broad variation of the different constellations of EDs in Denmark concerning the number of admissions per year, opening hours as well as visitation of patients. Patients suspected of having a heart disease (eg, acute myocardial infarction or arrhythmia) are either admitted to the ED or directly to the cardiology department. Both constellations are represented in this study. There is no upper limit to the number of inclusions per ED. There are one to five investigators per ED and each investigator is expected to include 20–25 patients. List of study sites can be obtained from the corresponding author.

Randomisation

Randomisation is performed using an online block randomisation database (REDCap OPEN) in which permuted blocks of random numbers have been listed to ensure an equal number of patients in both study arms at each centre.31 The allocation sequence of randomisation numbers is generated by the data manager from REDCap OPEN and the project manager, MR, using an online random number service.32 The randomisation numbers are then transferred into the REDCap OPEN database assigned to this study. The investigator registers each patient in the database whereby he receives the patient’s unique identification number and randomisation number which allocates the patient to either intervention or control group.

Investigators and educational programme

The local investigators are medical doctors who are either specialists or in specialist training and who receive patients in the ED on a regular basis. All the investigators use f-US in daily practice but have varying degrees of experience with f-US.

The project manager is responsible for educating the investigators in the data collection and the f-US protocol. This is undertaken as an e-learning presentation with instructional videos followed by a 4-hour onsite oral presentation of the project and the collection and registration of data as well as an individual evaluation of each investigator’s f-US skills (eg, by hands on).33 All investigators must pass a multiple choice questionnaire test and be able to perform the f-US protocol prior to initiation of inclusion (see online supplementary appendix IV). During the period of inclusion, investigators can take daily contact to the project manager with any question. Further supervision will take place if necessary.

The ultrasound protocol

To reduce the time spent on f-US, but still keep the focus on the specific signs of pathology of the heart and lungs, which we look for in the acute situation, we have modified the ultrasound protocols as follows.

The f-US of the lungs is a modification of the ultrasound protocol used by Laursen et al.3 It is originally modified from the principles of lung ultrasound by Volpicelli et al28 and Lichtenstein,34 and is performed as follows: the anterior and lateral part of thorax is divided into a superior and inferior quadrant. Each quadrant represents a zone in which the probe shall be placed centrally and create a transverse picture of the costae and pleura. A sequence of at minimum 4 s, including at least one inspiration and one expiration, shall be recorded in all zones.

The focused cardiac ultrasound is performed according to the principles described in the international evidence-based guideline.9 The views used are the four-chamber picture of the heart achieved either from a subxiphoid or an apical window. A sequence of minimum 6 s of the heart shall be recorded.

Blinding

To ensure a proper blinded audit of the medical record, we have instructed investigators and treating EP to leave all information regarding the patient’s unique identification number, randomisation number and f-US findings out of the medical record.

All f-US results from both groups are registered in the REDCap OPEN database only accessible for investigators and project managers.31 Only non-blinded f-US results are stored in an accessible briefcase in the ED for the EP to use.

Outcomes

Primary outcome

To investigate whether adding an f-US of the lungs and heart to the standard diagnostic examination in patients with signs and symptoms of respiratory problems increases the proportion of patients with a correct diagnosis established at 4 hours after admittance when f-US is performed by the local EP. The study will be performed as a randomised pragmatic multicentre trial.

Secondary outcomes

For the control and intervention group, we want to examine:

  1. The sensitivity, specificity, positive and negative predictive values and diagnostic accuracy of the primary presumptive diagnoses made upon arrival.

  2. The proportion of patients receiving a correct primary presumptive diagnosis made upon arrival.

  3. The proportion of f-US with a correct diagnostic assessment.

  4. The proportion of patients who within 4 hours after admission to the ED is given the correct treatment.

  5. Time spent in the ED (hours).

  6. Time spent at hospital (days).

  7. The proportion of patients being discharged from the ED and directly to their home.

  8. The proportion of patients being discharged from the ED to a hospital ward.

  9. The proportion of patients being discharged from the ED to the intensive care unit.

  10. The proportion of patients being readmitted to hospital within 30 days from discharge.

  11. In-hospital mortality.

  12. 30-Day mortality.

Sample size

The sample size estimate of this study is based on the results from the study by Laursen et al.3 We expect that ∼65% of the patients in the control group will have a correct presumptive diagnosis at 4 hours after admission to the ED. A clinically relevant absolute improvement of the tentative diagnosis using f-US in a multicentre study is set to be 15%. To detect a 15% increase in the number of correct tentative diagnoses, from 65% in the control group to 80% in the intervention group, with an 80% chance for detection and a level of significance of 5%, 272 included patients are needed. The estimated drop out is 6% and increases the number of inclusion to 288 patients. This gives 144 patients in each group (intervention/control group). Sample size calculations were made using the online database for clinical trials, Sealed Envelope.32

Data analysis

An intention-to-treat analysis will be performed on all participants and will serve as the primary analysis for all objectives in this study. In order to demonstrate a successful randomisation and the presence of even baseline groups, we register descriptive statistics (age, sex, smoking status, medical history, medication, triage colour) as well as clinical values and patient’s primary symptom on admission at the ED. Data will be specified as follows: categorical data by number and proportion of patients. Continuous data by number of patients (n), mean, SD, median, minimum and maximum. Missing data will be handled by the use of the statistical method multiple imputation.

Data analysis of primary end point

To determine whether there is a difference in the proportion of patients with a correct/incorrect presumptive diagnosis between the intervention group and the control group, we will use a χ2 test or the Fischer exact test.

Data analysis of secondary end points

To compare the intervention group with the control group, we will use the following tests: for the comparison of means, the Student's t-test; for the comparison of medians, the Mann-Whitney test; and for the comparison of proportions, the χ2 or the Fisher exact test. A two-sided significance level of 5% will be applied to all tests.

To assess the diagnostic accuracy of the primary presumptive diagnosis, the 4-hour presumptive diagnosis and the f-US, we will calculate the sensitivity, specificity, positive and negative predictive values and the diagnostic accuracy with 95% CI based at a binominal distribution. To assess the interobserver agreement on the f-US results between investigators and the ultrasound specialists, we use the Cohen’s κ coefficient. Data analysis will be conducted using STATA Release V.14.0 (Stata Corp) including professional statistical advice.

Data management

Data specified in the study protocol will be directly documented and securely stored in the password protected database assigned for this study in REDCap OPEN, SDU. REDCap is a secure web application designed to support data capture for research at which the University of Southern Denmark has its own secure database access.35 The project manager is responsible for the database construction in cooperation with a data manager from OPEN (SDU) as well as for data acquisition, storage, monitoring flow and validation.

In this database, each patient receives a unique identification number securing patient identity. The investigators will only gain access to this database to withdraw a randomisation number and to enter data regarding the inclusion/exclusion, basic values upon arrival, f-US findings and the primary presumptive diagnoses.

Additional clinical data will be available from the electronic patient records in which there is no information on the randomisation number or f-US findings. Basic characteristics will be entered into the database by the project manager. Data regarding the blinded audit of the medical records will be entered into the database by the auditors who have no access to other data entry forms than those regarding the blinded audit. A data monitoring committee was not used. All the data reported are linked to each specific investigator and data reporting are monitored by project manager, MR, on a weekly basis.

F-US findings will be stored on secured external hard drives where patients will be entered by their unique identification number to secure patient identity and to enable a blinded audit by the specialists in f-US. Only the patient’s informed consent for participation and non-blinded f-US findings are on paper format. No interim analysis or end point adjustments are planned. The final decision to end this trial before sample size is attained will be made by agreement between the project manager, MR, and her supervisors.

Ethics and dissemination

The f-US is a method of investigation which has no known adverse effects. It will be performed in accordance with the local hospital guidelines. To avoid deprivation of a diagnostic tool in the control group, we have taken the following precaution for all included patients because f-US is gaining ground in few of the participating EDs and because the f-US findings are blinded in the control group: in case any f-US rises suspicion of a life-threatening condition, the f-US findings will immediately be non-blinded to the EP in charge of the patient (box 2).

Box 2

Definition of adverse events leading to non-blinding of focused ultrasound examination results

For the purposes of this clinical trial, the definition of an adverse event/life-threatening condition will consist of any of the following:

  • Pulmonary oedema.*

  • Pneumothorax.

  • Large pleural effusion.†

  • Pericardiac effusion.‡

  • Heart failure.§

  • Suspected pulmonary embolism.

  • Aortic aneurysm/dissection.

*Identified as ≥3 B-lines in two or more scanning zones anterior or lateral on each lung.

†Affecting breathing.

‡>0.5 cm measured in diastole.

§Not previously known and with ejection fraction <45%.

The study will be conducted in accordance with the Helsinki II Declaration,36 and as approved by the Danish Data Protection Agency (identification number 13/12076),37 and the Committee on Biomedical Research Ethics for the Region of Southern Denmark (identification number S-20150090) with a dispensation from the normal rules for time for consideration since the f-US must be performed shortly after the patient has arrived to the ED. All data are stored and managed according to the laws and regulations of the Danish Data Protection Agency. The study is registered with Clinical trials (NCT02550184).

In the event that significant modifications to the protocol become necessary, MR will inform the coauthors, trial registers and investigators by mail and in person to ensure their implementation.

The results of this study will be published according to the CONSORT statement in peer-reviewed scientific journals regardless of the outcome.38

Strengths and limitations

The generalisability of this study is supported by the multicentre design with investigators comprised of local EP from many specialties. The investigators represent the general level of expertise in f-US nationwide. The sample size is powered to detect a clinically significant improvement in the proportion of patients with a correct diagnosis and the blinded journal audit is strengthened by inclusion of f-US findings in the assessment of the final diagnosis.

The study has limitations: the investigators are recruited via MR’s network of ultrasound enthusiasts. These doctors work in Danish EDs and they use ultrasound as part of their daily diagnostic procedures, but they cannot represent all doctors in the EDs. Furthermore, there is a risk of selection bias since patients are not consecutively enrolled. There is also a risk of non-blinding of f-US results before the primary or the 4-hour presumptive diagnosis has been attained since the investigators often hold the treatment responsibility. The study is not powered to investigate for differences in morbidity and mortality.

Conclusion

To our knowledge, this study is the first multicentre trial in the EDs to investigate whether an f-US in the hands of the EP can increase the proportion of patients with a correct diagnosis as well as the proportion of correctly initiated treatments on patients with signs of respiratory problems at 4 hours after their arrival to the ED. This trial holds the potential to develop evidence-based optimisation of early diagnostic accuracy in these patients.

Acknowledgments

MR would like to thank associate professor M Brabrand, MD, PhD and H Sheta, MD for their time spent on critical and professional inputs during the idea development of this study.

References

Footnotes

  • Contributors CBL, ATL, GB and MR contributed to the conception and design of the study. MR and CBL drafted the protocol and MR then wrote the protocol in accordance to the coauthors’ contributions. All authors approved the final draft of the protocol. MR is the project manager and in charge of all aspects of database management, education of investigators and conduction of inclusion. All authors contributed to the writing and the reviewing of this article.

  • Funding This trial is supported partly by the Department of Medicine/The Emergency Department and the Department of Surgery (A) at Odense University Hospital-Svendborg and partly by grants from the University of Southern Denmark, the PhD foundation at the Region of Southern Denmark and the Institute of Regional Research at Odense University Hospital-Svendborg. ATL is supported by an unrestricted grant from the philanthropic fund, the Tryg Foundation, given to the University of Southern Denmark.

  • Competing interests MR has been paid as instructor for courses in ultrasound organised by USabcd. CBL has received royalties from USabcd as author of e-learn material.

  • Ethics approval Approved by the Danish Data Protection Agency and the Regional Committees on Health Research Ethics for Southern Denmark.

  • Provenance and peer review Not commissioned; externally peer reviewed.