Accuracy of non-invasive prenatal testing using cell-free DNA for detection of Down, Edwards and Patau syndromes: a systematic review and meta-analysis
  1. Sian Taylor-Phillips1,
  2. Karoline Freeman1,
  3. Julia Geppert1,
  4. Adeola Agbebiyi1,
  5. Olalekan A Uthman1,
  6. Jason Madan1,
  7. Angus Clarke2,
  8. Siobhan Quenby1,
  9. Aileen Clarke1
  1. 1Warwick Medical School, The University of Warwick, Coventry, West Midlands, UK
  2. 2Institute of Cancer & Genetics, Cardiff University School of Medicine, Cardiff, UK
  1. Correspondence to Professor Aileen Clarke; aileen.clarke{at}warwick.ac.uk

Abstract

Objective To measure test accuracy of non-invasive prenatal testing (NIPT) for Down, Edwards and Patau syndromes using cell-free fetal DNA and identify factors affecting accuracy.

Design Systematic review and meta-analysis of published studies.

Data sources PubMed, Ovid Medline, Ovid Embase and the Cochrane Library published from 1997 to 9 February 2015, followed by weekly autoalerts until 1 April 2015.

Eligibility criteria for selecting studies English language journal articles describing case–control studies with ≥15 trisomy cases or cohort studies with ≥50 pregnant women who had been given NIPT and a reference standard.

Results 41, 37 and 30 studies of 2012 publications retrieved were included in the review for Down, Edwards and Patau syndromes. Quality appraisal identified high risk of bias in included studies, funnel plots showed evidence of publication bias. Pooled sensitivity was 99.3% (95% CI 98.9% to 99.6%) for Down, 97.4% (95.8% to 98.4%) for Edwards, and 97.4% (86.1% to 99.6%) for Patau syndrome. The pooled specificity was 99.9% (99.9% to 100%) for all three trisomies. In 100 000 pregnancies in the general obstetric population we would expect 417, 89 and 40 cases of Downs, Edwards and Patau syndromes to be detected by NIPT, with 94, 154 and 42 false positive results. Sensitivity was lower in twin than singleton pregnancies, reduced by 9% for Down, 28% for Edwards and 22% for Patau syndrome. Pooled sensitivity was also lower in the first trimester of pregnancy, in studies in the general obstetric population, and in cohort studies with consecutive enrolment.

Conclusions NIPT using cell-free fetal DNA has very high sensitivity and specificity for Down syndrome, with slightly lower sensitivity for Edwards and Patau syndrome. However, it is not 100% accurate and should not be used as a final diagnosis for positive cases.

Trial registration number CRD42014014947.

  • REPRODUCTIVE MEDICINE

This is an Open Access article distributed in accordance with the terms of the Creative Commons Attribution (CC BY 4.0) license, which permits others to distribute, remix, adapt and build upon this work, for commercial use, provided the original work is properly cited. See: http://creativecommons.org/licenses/by/4.0/

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Strengths and limitations of this study

  • This is a full systematic review with searches across multiple databases dating back to 1997, and two authors sifting all titles and abstracts.

  • Two authors extracted data on prepiloted forms and appraised quality using an adapted QUADAS 2 form.

  • The meta-analysis included rigorous methods of data analysis, including bivariate random-effects regression models, but required a zero-cell correction to enable model convergence which may underestimate rather than overestimate accuracy.

  • The meta-analysis included a series of subgroup and sensitivity analyses to test for robustness of our pooled diagnostic accuracy estimates.

  • The methods are transparent with full protocol published in PROSPERO in advance of the review.

Introduction

Non-invasive prenatal testing (NIPT) using cell-free fetal DNA (cffDNA) is a method for testing for trisomies in the fetus, using a peripheral sample of the pregnant mother's blood. It is currently marketed across 61 countries in Europe, Asia, Africa and North and South America.1 Rapid adoption in the USA has seen increases in first trimester screening using NIPT, and concurrent decreases in the first trimester combined test and invasive testing.2 ,3 People tend to overestimate the usefulness of genetic tests, and misinterpret their meaning.3 It is possible that pregnant women will interpret a positive NIPT test as positive diagnosis, and wish to abort a pregnancy on this basis. A clear summary of test accuracy for NIPT is necessary for use by doctors and patients for use in shared and informed decision-making.

Although a previous review of NIPT test accuracy exists,4 it does not include two of the largest studies.5 ,6 In addition the authors use a univariate approach which is not appropriate for meta-analysis of tests since it overlooks the fact that sensitivity and specificity are usually negatively correlated across studies due to different thresholds used to define positive and negative test results. It has been shown that ignoring this correlation would be inappropriate.7 The weighted sums of the reported specificity are normally used to assess the value of a test, the properties of the resulting statistics depends most importantly on this correlation between the estimates, and it is exactly that is ignored in separate univariate analyses.8 ,9 Most importantly, the previous review does not provide a summary of findings which can be applied to a relevant population and used in clinician–patient shared decision-making.

The UK National Screening Committee commissioned this new review to provide a summary of the accuracy of NIPT for detection of Down, Edwards and Patau syndromes in first trimester pregnancies, to inform their decision on introduction of this test into current fetal abnormality screening in the UK.

Methods

Identification and selection of studies

Ethical approval was granted from the University of Warwick Biomedical and Scientific Research Ethics Committee reference REGO-2015-1446. Searches were conducted in PubMed, Ovid Medline, Ovid Embase and the Cochrane Library. The search strategy used a combination of search terms for the NIPT test and trisomies, and was limited to the English language, (see online supplementary file 1). Date limits were 01.01.1997–09.02.2015. Updating autoalerts in Medline and Embase were run until 01.04.2015. Individuals and organisations were contacted for studies not freely available in the public domain. ClinicalTrials.gov, WHO International Clinical Trials Registry Platform (ICTRP) Search Portal and meeting abstracts were also searched for ongoing or recently completed trials.

Two reviewers independently screened titles and abstracts of all records obtained. Discrepancies were resolved by consensus or discussion with a third reviewer. Inclusion criteria were English language journal articles which investigated NIPT using cff DNA derived from maternal blood (serum, plasma, whole blood) in pregnant women in any trimester for the detection of Down (T21), Edwards (T18) or Patau (T13) syndromes in the fetus. The reference standard was genetic verification through amniocentesis, Chorionic Villus Sampling (CVS), cordocentesis, fetal pathological examination after abortion or postnatal phenotypic assessment. We included studies with any outcomes reported on test accuracy, or rates of test failure or indeterminate results. We excluded studies reporting the quantification of fetal cells or DNA or using elevated levels of the whole fetal DNA or epigenetic markers. We also excluded case–control studies with fewer than 15 cases and cohort studies with fewer than 50 pregnant women as well as studies with incomplete 2×2 data or studies which reused samples from other included studies in order to prevent double counting.

Data were extracted by one reviewer and checked by a second reviewer. Disagreements were resolved by consensus or discussion with a third reviewer. Full data extraction forms are available from the authors on request.

Quality assessment

The quality of diagnostic accuracy studies was assessed using a modified QUADAS-2.10 Quality assessment was undertaken by one reviewer and checked by a second reviewer, with disagreements resolved by a third reviewer. Three modifications were made. First, an additional signalling question was added on whether the study avoided taking the sample for the index test in the 7 days after an invasive test, as fetal fraction may be elevated at this time boosting the performance of NIPT. Second, a signalling question was added to determine whether the threshold value was determined using an independent set of samples, and whether adjustment of the predefined threshold was avoided, since the threshold for testing positive is expressed as number of SDs from the mean score for a set of normal samples, rather than as an absolute threshold. Finally, the standard QUADAS-2 signalling question determining whether there was an appropriate interval between index test and reference standard was removed, as timing of an invasive test (apart from in relation to invasive testing) would not affect accuracy. Timing of the NIPT test is important as fetal fraction and therefore accuracy of NIPT increases throughout pregnancy, this was included under applicability of findings rather than as a source of bias. We also assessed the role of the sponsor in addition to QUADAS-2. This included studies that clearly declared involvement of a sponsor in the design or conduct of the study or publication, the majority of authors were employees or shareholders of companies offering NIPT or cytogenetic tests and/or other conflicts of interest (ie, patents, stock or stock options). Please see online supplementary file 2 for full information on the definition for the signalling questions of the QUADAS-2.

Statistical analysis of test accuracy studies

All eligible studies were included in a meta-analysis of performance of the NIPT test. We extracted data from the primary studies to obtain the four cell values of a diagnostic 2×2 table in order to calculate test accuracy measures. We pooled the sensitivity and specificity estimates using bivariate random-effects regression models, as recommended by the Cochrane Diagnostic Test Accuracy Working Group,11 in order to take the potential trade-off between sensitivity and specificity explicitly into consideration and incorporate this negative correlation into the analysis.7 We added a 0.5 cell correction to each cell where a zero was encountered. We stratified test accuracy measures according to condition (T21, T18 and T13).

Meta-analysis, subgroup and sensitivity analyses

We used sensitivity, subgroup and meta-regression analyses to explore potential sources of heterogeneity in test accuracy estimates across studies. The following variables were selected a priori as potential sources of heterogeneity: study design (cohort with consecutive sampling vs others), population risk (general, high-risk, others), population (twins vs others), first trimester (100% vs other), test type (MPSS, DANSR, single nucleotide polymorphism (SNP) technology) and publication year (2007–2013 vs 2014–2015). We conducted a series of sensitivity analyses to check the robustness of the results. We excluded all studies with zero cases of true positive and false negative results. We used Cook's distance to identify particularly influential studies and created a scatter plot of the standardised predicted random effects (standardised level 2 residuals) to check for outliers.12 We refitted the model leaving out outliers and very influential studies.

We constructed 3×2 tables to examine the influence of the number of test failures and indeterminate results on the pooled test accuracy estimates.13 Test failures occur where the NIPT test has failed to produce any result, and indeterminate results where the test result is in a mid-range which is neither positive nor negative. Test failures can occur for a variety of reasons, and sometimes the cause is unknown. Test failures and indeterminate results are not included in the 2×2 tables reported, and this can lead to overestimates of sensitivity and specificity.14 We included all failures of the NIPT test, regardless of whether repeating the test on the same or a new blood sample would have given a result, but we did not include failures which could be rectified by good quality assurance procedures (such as insufficient blood or dropped samples). For the 3×2 tables we considered the following three scenarios, all non-evaluable results: (1) considered to be positive results to reflect use of the NIPT as triage for invasive testing,14 (2) considered to be negative results to reflect use of NIPT as an add-on to the combined test14 and (3) follow intention to diagnose principle to account for the first two approaches overestimating specificity and sensitivity, respectively.13 Intention to diagnose was defined as “including non-evaluable results either in the ‘false negative’ or the ‘false positive’ cell of a 2×2 table (worst case scenario) according to the results of the reference standard”. For the intention to diagnose principle, all non-evaluable positive results were assumed to be false negative and all non-evaluable negative results were assumed to be false positive. Where the reference standard results were not reported for these cases, we assumed that they had the same prevalence of trisomy as those in the rest of the same study.

In the subgroup analyses, we computed pooled accuracy estimates in various strata to determine if accuracy is higher or lower in specific subgroups. Summary sensitivity and specificity estimates for each subgroup were generated, along with their 95% CIs. In the linear meta-regression model, studies are the units of analysis. We used the meta-regression model to generate relative diagnostic ORs.15 ,16 We used Deeks’ funnel plot asymmetry test to test for publication bias, with p value<0.10 indicating significant publication bias.17 All analyses were performed using Stata V.13 for Windows including the user written commands metandi, midas, metareg and mvmeta.12 ,18–20

Results

Study selection

A total of 2012 records were identified after duplicates were removed. One-hundred and eight records remained after evaluation of title and abstract, of which 41 studies were included in the meta-analysis. Figure 1 summarises the study selection process (see online supplementary file 3 for included studies and online supplementary file 4 for reasons of exclusion for 67 full-text articles).

Figure 1

Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) flow chart of included articles.

Characteristics of included studies

Study design, populations, reference standards

Forty-one publications, dating from 2007 to 2015, reported NIPT results for between 46 and 112 669 pregnant women for the main autosomal trisomies in relation to fetal karyotype or newborn phenotype and fulfilled our inclusion criteria (see online supplementary file 5). The majority of studies were cohort studies (n=29),5 ,6 ,21–47 with prospective data collection. There were 11 case–control studies48–58 and one of unclear design.59 Thirty studies were undertaken in singleton pregnancies only,6 ,21 ,22 ,29–33 ,35–37 ,40–51 ,53–59 four studies included singleton and twin pregnancies,5 ,28 ,34 ,38 with the remainder undertaken in twin only (n=3).23 ,24 ,39 In four studies the reporting was unclear.25 ,26 ,28 ,52 The majority of studies (n=24) used samples from high-risk pregnant women (positive standard screening, ultrasound abnormalities, advanced maternal age, personal or family history of aneuploidies) undergoing invasive testing.24 ,26 ,28 ,30 ,31 ,33 ,36–38 ,41 ,44 ,45 ,47–56 ,58 ,59 Six studies were performed in the general obstetric population.6 ,21 ,29 ,35 ,40 ,43 Nine studies included pregnant women with mixed risk factors.5 ,22 ,27 ,32 ,34 ,39 ,42 ,46 ,57 In two the underlying risk was unclear.23 ,25 Seven studies included women in the first trimester only,6 ,23 ,29 ,30 ,43 ,47 ,48 while all other studies (n=34) included pregnant women with an unstated, later or broader gestational age window.5 ,21 ,22 ,24–28 ,31–42 ,44–46 ,49–59

Testing strategies

Three main testing strategies were pursued by the majority of studies (see online supplementary file 6). These were genome-wide massively parallel shotgun sequencing (MPSS, n=24 studies),5 ,21 ,22 ,24–28 ,33–36 ,41 ,44–47 ,49–52 ,54 ,55 ,58 targeted massively parallel sequencing (DANSR, n=9 studies),6 ,23 ,29 ,31 ,37 ,39 ,43 ,48 ,56 and SNP technology (n=5).30 ,32 ,42 ,53 ,57 Two studies, performed in real clinical settings, offered more than one NIPT approach.38 ,40 Dhallan et al59 used a DNA-SNP allelic ratio approach.

In 3 of the 41 studies,21 ,32 ,57 some of the maternal blood samples for NIPT were obtained after invasive testing and for 34 studies we concluded that tests were collected before the invasive testing.5 ,6 ,22–24 ,26–31 ,33–52 ,54 ,55 ,58 In four studies, it was unclear if maternal blood sampling for NIPT was performed before or after an invasive procedure.25 ,53 ,56 ,59

Forty studies reported NIPT performance for T21,5 ,6 ,21–49 ,51–59 36 for T18,5 ,6 ,21–36 ,38–50 ,53–57 and 30 studies investigated non-invasive detection of T13.5 ,6 ,21 ,23 ,25–28 ,30 ,32–36 ,38–47 ,49 ,50 ,53–55 ,57 Twenty-nine studies reported test accuracy for all three main autosomal trisomies.5 ,6 ,21 ,23 ,25–28 ,30 ,32–36 ,38–47 ,49 ,53–55 ,57

Methodological quality of included studies

The methodological quality of the 41 included studies, assessed by QUADAS-210 is summarised in figures 2 and 3 and online supplementary file 7. Risk of bias was high in most studies with 25 of 41 studies considered high risk in two or more domains, and 14 studies in one domain. Two were judged as low or unclear risk of bias in all five domains. Figure 2 shows that study flow (concerned with patient follow-up) and the role of the sponsor were the areas with the greatest risk of bias. Another issue was incomplete or unclear reporting, particularly of the patient selection process and the conduct of the index test, which is reflected in 21 (51.2%) and 14 (34.1%) of 41 publications scoring an unclear risk of bias in these two domains, respectively. The risk of bias regarding the reference standard was considered low in almost all studies with only one study classified as unclear.23 Finally, risk of bias regarding the role of sponsor was deemed high in 23 studies. There were significant concerns regarding applicability of the included patient spectrum to cffDNA testing introduction in the first trimester (see figure 3), as 29 of 41 studies had significant parts (>20%) of their populations tested in the second or third trimester when fetal fraction and therefore accuracy of NIPT is higher.

Figure 2

Proportion of studies with low, high or unclear risk of bias using QUADAS 2.

Figure 3

Proportion of studies with low, high and unclear concerns regarding applicability using QUADAS 2.

Meta-analysis

There was a high likelihood of publication bias, with the slope coefficients on Deeks’ funnel plot asymmetry test significant for Down syndrome (p=0.0001), Edwards syndrome (p=0.0001), and Patau syndrome (p=0.045) (see figure 4).

Figure 4

Deeks’ funnel plot for Down (left) Edwards (centre) and Patau (right) syndromes. A vertical pattern would indicate no bias, slope is associated with publication bias.

The pooled sensitivity for Down syndrome from bivariate random-effects regression of 40 studies was 99.3% (98.9% to 99.6%) and the pooled specificity was 99.9% (99.9% to 100%). For Edwards syndrome the pooled sensitivity over 33 studies was 97.4% (95.8% to 98.4%) and specificity was 99.9% (99.9% to 100%). For Patau syndrome the pooled sensitivity over 24 studies was 97.4% (86.1% to 99.6%) and specificity was >99.9% (99.9% to 100%). Table 1 shows these pooled sensitivities and specificities applied to populations of pregnant women taking the test. In the subgroup analysis (table 2) sensitivity estimates were lower by 6.1% for Down, 10.6% for Edwards, and 12.3% for Patau syndromes for cohort studies with consecutive sampling in comparison to all other studies which are more likely to be subject to spectrum bias. Test accuracy did not appear to systematically differ between DANSR, MPSS or SNP-based test types or by publication year. Estimates of test sensitivity were higher in high-risk populations, in studies including pregnancies in the second and third trimester, and in singleton pregnancies. In high-risk populations, defined in a variety of ways, pooled sensitivity estimates were 1.4%, 6.5% and 17.8% higher than in the general obstetric population for Down, Edwards and Patau syndromes, respectively. Sensitivity estimates were 1.3%, 1.4% and 11.6% lower in studies recruiting all women in their first trimester of pregnancy in comparison to studies including women later in pregnancy. The outcomes of test accuracy of the included studies are summarised in online supplementary file 8. A forest plot of the sensitivity and specificity from the individual studies with 95% CIs is given in figure 5.

Table 1

Summary of findings applied to high risk and general obstetric population

Table 2

Accuracy estimates from sensitivity and subgroup analyses of the included studies by different study characteristics†

Figure 5

Individual and pooled sensitivity and specificity for non-invasive prenatal testing (NIPT) for the detection of a. Down syndrome b. Edwards syndrome and c. Patau syndrome.

Test failures

The rate of analytic failure (failure of the cffDNA testing) ranged from 0% to 12.7%57 and among 5789 pregnancies with resampling, 803 (13.9%) also failed the repeat cffDNA testing. There were five papers in this review that reported indeterminate results (results in a range defined as neither positive nor negative) for trisomies 21, 18 and 13.21 ,38 ,49 ,55 ,60 ranging from 0% (0/2042) to 11.1% (5/45). In the study with no indeterminate results they used eight-plex testing, and where the initial score was indeterminate they repeated using one-plex which corrected any indeterminate results. There is some evidence that the rate of test failure is higher when gestational age is lower, and in trisomic pregnancies. Pergament et al32 found that failure rate at <9 weeks was 26/95 (27.4%), between 9.0 and 9.9 weeks was 6/50 (12.0%), and more than 10 weeks was 53/900 (5.9%). The same study found aneuploidy incidence was increased (20/86 (23.3%)) in samples that did not return a result when compared with the aneuploidy incidence in samples with a cffDNA testing result (105/966 (10.9%), p=0.004). Norton et al6 did not find an association between test failure and gestational age in 18 510 women between 10 and 14 weeks gestation, but found that the prevalence of aneuploidy in the group with test failure (1 in 38 (2.7%)) was higher than the prevalence of 1 in 236 (0.4%) in the overall cohort (p<0.001).

Including test failures in an intention to diagnose analysis in the meta-analysis decreased sensitivity estimates by 1.7% for Down, 1.6% for Edwards and 7.1% for Patau syndrome, and decreased specificity estimates by nearly 2% for all three trisomies. Excluding test failures from the calculations of test accuracy may have caused overestimation of accuracy. Similarly in the subgroup analysis sensitivity estimates were lower by 6.1% for Down, 10.6% for Edwards, and 12.3% for Patau syndromes for cohort studies with consecutive sampling in comparison to all other studies. Test accuracy did not appear to differ systematically between DANSR, MPSS or SNP technology, or by publication year. Estimates of test sensitivity were higher in high-risk populations, in studies including pregnancies in the second and third trimester, and in singleton pregnancies. In high-risk populations, defined in a variety of ways, pooled sensitivity estimates were 1.4%, 6.5% and 17.8% higher than in the general obstetric population for Down, Edwards and Patau syndromes, respectively. Sensitivity estimates were 1.3%, 1.4% and 11.6% lower in studies recruiting all women in their first trimester of pregnancy in comparison to studies including women later in pregnancy. Twin pregnancies had 8.3% lower sensitivity estimates than singletons for Down syndrome. This difference was 20.6% for Edwards syndrome, but there was only one study for Patau syndrome so we were unable to provide a pooled estimate for twins. Sensitivity and subgroup analyses are reported in table 2.

Discussion

In a systematic review of 2012 articles, we identified 41 articles on the test accuracy of NIPT. Quality appraisal using QUADAS-2 indicated high risk of bias, in particular due to unclear or unsystematic inclusions and exclusions of participants at study entry level as well as at the level of analysis. Applicability of findings was of concern as there is still very limited data on the screening population available. Pooled sensitivity from the meta-analysis was 99.3% for T21, 97.4% for T18 and 97.4% for T13, with pooled specificity 99.9% (99.9% to 100%) for all three trisomies. We estimated test accuracy in a high-risk population of 10 000 pregnancies where 3.3% of fetuses have Down syndrome, 1.5% have Edwards syndrome and 0.5% have Patau syndrome. There would be 324 cases of Down syndrome detected, with 9 missed and 31 false positive results, 140 cases of Edwards syndrome detected with 11 missed and 26 false positive results, and 47 cases of Edwards syndrome detected, with 3 missed and 7 false positive results (table 1). In the general obstetric population where prevalence of trisomy is lower, there would be a lower positive predictive value. In 100 000 pregnancies in the general obstetric population we would expect 417, 89 and 40 cases of Downs, Edwards and Patau syndromes to be detected by NIPT, with 94, 154 and 42 false positive results. Therefore it is vital to follow a positive NIPT test with an invasive diagnostic test (amniocentesis or CVS) to confirm the presence of trisomy, if the woman is considering termination of pregnancy on the basis of trisomy.

The strengths of this systematic review included a comprehensive search of the literature, with quality appraisal of all included studies, with two authors sifting studies for inclusion, extracting data and appraising quality. The meta-analysis included rigorous methods of data analysis, including bivariate random-effects regression models and HSROC curve analysis. We also conducted a series of subgroup analyses and sensitivity analyses to test for robustness of our pooled diagnostic accuracy estimates. Homogeneous subgroup and sensitivity analysis summary accuracy estimates were generally similar to the overall estimates. We added predefined covariates to the model using meta-regression analyses to explain heterogeneity but considerable statistical heterogeneity remained. For some of the subgroup analyses, the relatively small number of studies available limited the generalisability of such pooled accuracy estimates. Finally we applied zero cell continuity correction of 0.5 to each cell of a study where a zero is encountered which tends to underestimate rather than overestimate test accuracy.

The findings of our review are in line with the results from previous reviews stating that NIPT has high performance in terms of sensitivity and specificity,61 ,62 that specificity is slightly higher than sensitivity,61 that the test performance is greater for T21 than for T18 and T13,4 and that NIPT is less successful in twin pregnancies than in singleton pregnancies.4 However, we found evidence of significant publication bias, converted results into a format interpretable by clinicians, and concluded that the test is not diagnostic. There are two key differences between our review and the previous publications. First, we included more studies, several of which have been published since the most recent review4 (including two of the largest studies with test accuracy for 128 510 women).5 ,6 Second, the two previous reviews conducted separate pooling of the diagnostic test accuracy measures using a univariate approach using standard methods for proportion4 ,62 which is not recommended for reviews of test accuracy. Berkey et al63 show that a bivariate meta-regression is more efficient than separate univariate meta-regressions for assessing study-level covariates, due to the inclusion of correlation. We used Deeks’ funnel plots and found evidence of publication bias, whereas the previous review used an Egger's bias applied to sensitivity and specificity separately and found no evidence of bias, although their method may not be appropriate for studies of test accuracy.17 Studies with a larger effective sample size tended to report higher diagnostic ORs. This may be due to publication bias in large laboratory cohort or case–control studies with a lack of systematic or consecutive sampling, or the fact that studies in the general obstetric population tend to have lower test accuracy and fewer cases. It may be partly due to our methods in that the zero-cell correction may disadvantage small studies, or simply that the test is performed to a higher standard in larger studies, perhaps due to more advanced protocols used in later large scale studies.

The implications for policymakers and clinicians are that NIPT using cffDNA has very high sensitivity and specificity, and can contribute to screening programmes for Down, Edwards and Patau syndromes. It is clear that test accuracy is very good but not perfect. This is particularly true when considering populations in terms of risk and gestational age. Our subgroup analyses showed that test performance is better in high-risk populations as well as in studies including pregnancies in the second and third trimester. Consideration of NIPT as a screening test for the general obstetric population primarily tested in the first trimester of pregnancy has to take into account the lower sensitivity of NIPT in this population. There is also some indication that higher maternal weight, and conception by in vitro fertilisation (IVF) are potential predictors of NIPT test failure39 suggesting that NIPT may not work equally well in all subpopulations. We consider that for this reason cffDNA should not be regarded as a diagnostic test and that confirmation of a positive NIPT result by amniocentesis or CVS is necessary to make a diagnosis of trisomy. This is essential if parents are considering termination of pregnancy on the basis of trisomy, because in the general obstetric population as many as 20% of positive NIPT results for Down syndrome may be false positive. This proportion will be higher for Edwards and Patau syndromes. Because the source of cffDNA is the placenta, confined placental mosaicism may explain a proportion of discordant NIPT results.64 Furthermore, early fetal demise of an affected fetus53 ,64 and unknown chromosomal abnormality in the mother5 ,64 can lead to false positive results. Finally, in some cases discordance between NIPT and fetal karyotype results might be due to lab error.64 The role of low fetal fraction as contributor to false positive or false negative results is unclear: Zhang et al5 reported no major influence, whereas Quezada et al43 found lower fetal fractions in discordant than in those with concordant results.

Communicating to clinicians and patients that this genetic test is not perfect will be key for safe implementation, and pretest and post-test information provision and counselling for positive and negative NIPT results should be given careful consideration. The NIPT test may be particularly attractive to parents who are not considering termination of pregnancy, but who would like to know in advance if their pregnancy is affected by a trisomy, since NIPT gives broadly accurate results, without the slightly increased risk of miscarriage associated with invasive procedures such as amniocentesis and CVS. The final consideration for implementation is the range of test failure rates from <1% to >12%, with some evidence that presence of trisomy may be a predictor of test failure. Quality assurance to minimise test failures would minimise delays due to repeated testing, which may be a priority for pregnant women. However, if the test failure is due to insufficient fetal fraction a retest is also likely to fail.

This test is used worldwide, mostly provided directly by private providers rather than national health systems. Further research into how the test is being interpreted and understood by clinicians and pregnant women will be key to understanding the balance of benefits and harms from the provision of the test. In particular, how this understanding leads to decisions about whether to continue the pregnancy, and whether this may be influenced by how the test is presented to parents both by companies, and by clinicians. Finally if it is implemented into national screening programmes, keeping accurate records of outcomes and test failures would enable the test performance to be evaluated in practice. This may differ from the test accuracy in the included studies in this paper, due to the high risk of bias in included studies of cffDNA, and the unexplained heterogeneity illustrating the uncertainties in transferring results from research studies into everyday practice.

Acknowledgments

The authors would like to thank Jill Colquitt and Emma Loveman from Effective Evidence LLP, Eastleigh, for sourcing parameters for the economic model, Paul Hewitson for his work on the search strategy and sifting, Frances Taggart for her work on test accuracy at different thresholds, and Pam Royle for her work updating the searches.

References

View Abstract

Supplementary materials

Footnotes

  • Contributors STP led the research design and implementation. JG and AA sifted and quality appraised the studies. OA conducted the meta-analysis. All authors contributed to study design, data collection and interpretation, and writing and redrafting the paper, and approved the final version of the paper.

  • Funding This is independent research commissioned by the UK National Screening Committee. Sian Taylor-Phillips is supported by a clinical trials fellowship from the National Institute for Health Research (NIHR). Aileen Clarke is supported by the National Institute for Health Research Collaboration for Leadership in Applied Health Research and Care West Midlands at University Hospitals Birmingham NHS Foundation Trust. The views expressed in this publication are those of the authors and not necessarily those of the NHS, the National Institute for Health Research, the UK National Screening Committee, Public Health England or the Department of Health. Any errors are the responsibility of the authors.

  • Competing interests None declared.

  • Provenance and peer review Not commissioned; externally peer reviewed.

  • Data sharing statement No additional data are available.