The Otto Aufranc Award. Highly cross-linked polyethylene in total hip arthroplasty: randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis

Clin Orthop Relat Res. 2004 Dec:(429):6-16.

Abstract

The annual wear rate in polyethylene articulations should be 0.1 mm or less to avoid future osteolysis. Highly cross-linked polyethylene shows an 80 to 90% wear reduction in hip simulator testing, but the clinical documentation of this new polyethylene is still inadequate. We evaluated the highly cross-linked polyethylene in two prospective randomized clinical studies. Thirty-two patients (12 men, 20 women; 64 hips) with a median age of 48 years (range, 29-70 years) with bilateral primary or secondary arthrosis of the hip had hybrid total hip arthroplasty with liners made of highly cross-linked polyethylene on one side and conventional polyethylene on the other. Twenty-seven patients in this study have passed 2 years followup. A further group, comprised of 60 patients (61 hips) with a median age of 55 years (range, 35-70 years), was randomized to receive either highly cross-linked polyethylene or conventional cemented all-polyethylene of the same design. Forty-nine of these 60 patients have been observed for 3 years. In both studies all patients received Spectron stems with 28-mm Co-Cr heads. Radiostereometric examinations with the patient supine or standing were done at regular intervals. Wear was measured in the supine position from the first postoperative week, whereas standing examinations were initiated 3 months after the operation. The penetration rate almost was identical in the study and control groups at 6 months after the operation. Thereafter, the penetration rate leveled out in the two groups with highly cross-linked polyethylene. At 2 years the highly cross-linked polyethylene liner showed 62% lower proximal penetration and 31% lower total (three-dimensional) penetration when the patients were examined in supine position. The highly crosslinked all-polyethylene cemented cups showed lower proximal penetration in both positions. The better wear performance of highly cross-linked polyethylene could increase the implant longevity. Longer followup is needed to evaluate if this new material is associated with less occurrence of osteolysis.

Publication types

  • Clinical Trial
  • Comparative Study
  • Evaluation Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't
  • Review

MeSH terms

  • Adult
  • Aged
  • Arthroplasty, Replacement, Hip / methods*
  • Awards and Prizes
  • Bone Cements*
  • Female
  • Follow-Up Studies
  • Hip Prosthesis*
  • Humans
  • Male
  • Middle Aged
  • Osteoarthritis, Hip / diagnostic imaging
  • Osteoarthritis, Hip / surgery*
  • Polyethylene*
  • Probability
  • Prosthesis Design
  • Prosthesis Failure
  • Radiography
  • Randomized Controlled Trials as Topic
  • Range of Motion, Articular / physiology
  • Recovery of Function
  • Risk Assessment
  • Severity of Illness Index
  • Statistics, Nonparametric
  • Sweden
  • Time Factors
  • Treatment Outcome

Substances

  • Bone Cements
  • Polyethylene