Table 2

Prevalence of kidney organ failure on the last day of follow-up (‘standard-exposure’ group vs ‘high-exposure’ group)

Standard-exposure groupHigh-exposure groupp Value
Survivors and patients who had last creatinine measured >24 h before deathN=432N=438
Renal failure (*eGFR: ≤60 ml/min/1.73 m2)119 (27.6%)137 (31.3%)0.23
Patients who died (with last creatinine measured within 24 h before death)N=150N=145
Renal failure (eGFR: ≤60 ml/min/1.73 m2)105 (70.0%)99 (68.3%)0.83
All patients with creatinine measurementsN=582N=583
Renal failure (eGFR: ≤60 ml/min/1.73 m2)224 (38.5%)236 (40.5%)0.51
  • * eGFR was assessed using the Cockcroft and Gault method (Ref: Cockcroft DW, Gault MH: Prediction of creatinine clearance from serum creatinine. Nephron 1976;16:31–41). Actual measured creatinin values were used.

  • eGFR, estimated glomerular filtration rate.