Table 4

Correlation between macular and GCL structural measurements and colour vision evaluated with Lanthony colour test in patients with Parkinson's disease

Lanthony colour test
C-indexp ValueCCIp ValueS-indexp Value
Macular thickness
 Central−0.0190.905−0.0590.716−0.0170.915
 Inner superior−0.1460.369−0.1190.463−0.1670.302
 Inner nasal−0.0550.735−0.0440.788−0.0400.807
 Inner inferior−0.0730.654−0.0640.697−0.0740.649
 Inner temporal−0.0490.764−0.0310.850−0.1260.439
 Outer superior0.3770.0170.3800.015−0.2710.090
 Outer nasal0.3410.0310.3230.042−0.3100.051
 Outer inferior0.3600.0220.3530.0250.3750.017
 Outer temporal0.3600.0230.3610.0220.3500.027
 Macular average0.6910.0190.6570.0280.7090.015
 Macular volume0.6860.0200.6470.0320.7090.015
GCL thickness
 Superior0.3800.0150.3690.019−0.2870.072
 Superonasal0.3830.0150.3370.0330.3500.027
 Inferonasal0.3380.0330.3130.049−0.2680.094
 Inferior0.3410.031−0.3110.051−0.2820.078
 Inferotemporal−0.2520.116−0.2630.101−0.2030.208
 Temporal0.4030.0100.4370.0050.3140.048
 Average IPL+GCL0.3810.0150.3580.0230.3190.045
 Minimum IPL+GCL0.3380.0330.3260.040−0.2900.069
  • Data in bold type correspond to statistically significant correlations (p<0.05). CCI, colour confusion index; C-index, confusion index; GCL, ganglion cell layer; IPL, inner plexiform layer; S-index, scatter index.