Article Text

Download PDFPDF

Retrospective morphometric study of the suitability of renal arteries for renal denervation according to the Symplicity HTN2 trial criteria
  1. Elisabeth Schönherr1,
  2. Rafael Rehwald1,
  3. Parinaz Nasseri2,
  4. Anna K Luger1,
  5. Astrid E Grams3,
  6. Julia Kerschbaum4,
  7. Peter Rehder5,
  8. Johannes Petersen1,
  9. Bernhard Glodny1
  1. 1Department of Radiology, Medical University of Innsbruck, Innsbruck, Tyrol, Austria
  2. 2University Clinic of Oral and Maxillofacial Surgery, Salzburg General Hospital, Salzburg, Salzburg, Austria
  3. 3Department of Neuroradiology, Medical University of Innsbruck, Innsbruck, Tyrol, Austria
  4. 4Department of Internal Medicine IV, Nephrology and Hypertensiology, Medical University of Innsbruck, Innsbruck, Tyrol, Austria
  5. 5Department of Urology, Medical University of Innsbruck, Innsbruck, Tyrol, Austria
  1. Correspondence to Professor Johannes Petersen; johannes.petersen{at}i-med.ac.at

Abstract

Objective The aim of this study was to describe the renal arteries of humans in vivo, as precisely as possible, and to formulate an expected value for the exclusion of renal denervation due to the anatomical situation based on the criteria of the Symplicity HTN trials.

Design and setting In a retrospective cohort study, the renal arteries of 126 patients (57 women, 69 men, mean age 60±17.2 years (CI 57.7 to 63.6)) were segmented semiautomatically from high-contrast CT angiographies.

Results Among the 300 renal arteries, there were three arteries with fibromuscular dysplasia and one with ostial renal artery stenosis. The first left renal artery was shorter than the right (34±11.4 mm (CI 32 to 36) vs 45.9±15 mm (CI 43.2 to 48.6); p<0.0001), but had a slightly larger diameter (5.2±1.4 mm (CI 4.9 to 5.4) vs 4.9±1.2 mm (CI 4.6 to 5.1); p>0.05). The first left renal arteries were 1.1±0.4 mm (CI 0.9 to 1.3), and the first right renal arteries were 0.3±0.6 mm (CI 0.1 to 0.5) thinner in women than in men (p<0.05). Ostial funnels were up to 14 mm long. The cross-sections were elliptical, more pronounced on the right side (p<0.05). In 23 cases (18.3%), the main artery was shorter than 2 cm; in 43 cases (34.1%), the diameter was not >4 mm. Some 46% of the patients, or 58.7% when variants and diseases were taken into consideration, were theoretically not suitable for denervation.

Conclusions Based on these precise measurements, the anatomical situation as a reason for ruling out denervation appears to be significantly more common than previously suspected. Since this can be the cause of the failure of treatment in some cases, further development of catheters or direct percutaneous approaches may improve success rates.

  • RADIOLOGY & IMAGING

This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.